HR100W/HR100WH
Installation in bathrooms/WC’s
Meets buildings regulations for bathrooms and WC’s
Eliminates mould
Controls condensation
70% Heat recovery
The Vent-Axia HR100W range is designed for continuous operation providing up to 70% Heat Recovery. Effectively controlling internal relative humidity. The Vent-Axia HR100WH unit come complete with
integral humidity sensor and controls condensation and reduces mould.
Fresh pre-warmed air from the outside is continuously provided to the room with simultaneous extraction of stale, moist air.
An integral heat exchanger transfers heat from the outgoing stale air to the fresh air supply, raising the temperature of the fresh air and most importantly reducing the Relative Humidity of the supply air to the room.
The HR100WH has a two speed motor which provides for constant low rate
ventilation automatically switching to boost speed on rising humidity level of approximately 70% relative humidity at 20°C. This level can easily be adjusted by removing the front cover and heat exchanger to reveal the adjustment spindle.
Typical Installation
Extract Performance
m³/h
Intake Performance
m³/h
Watts
Sounds Levels
dB(A) @ 3m
Boost
Trickle
Boost
Trickle
Boost
Trickle
Boost
Trickle
73
43
69
38
31
12
30
20
HR100W units require a 240mm x 160mm hole. The unit should be fitted so that it slopes towards the outside (nominal 1°) to assist in-built condensate drainage.
The telescopic flange (adjustable to fit walls 220mm to 280mm thick) covers cutting marks and provides a surface for forming a seal with the external wall surface. An extension sleeve is available for thicker walls up to 500mm. (Stock Ref. 370419)
Maintenance
Filters should be replaced every six months or as conditions necessitate. Replacement filters can be purchased in packs of four. (Stock Ref. No. 37 03 78).The heat exchanger should be washed in warm soapy water every twelve months or as conditions necessitate. Access to the filter and heat exchanger is via two screws on the internal grille.
Power Consumption
Trickle
12.0W
Boost
31.0W
DIMENSIONS:
Weight: 4.85kg
A | B | C | D | E | F | G |
370 | 270 | 220-280 | 68 | 155 | 235 | 190 |
With built-in Humidity Sensor A surface mounted heat recovery ventilation unit for use in bathrooms and toilets, meeting building regulations for this application. Up to 77m³/h capacity (balanced airflow).
Provides balanced ventilation with heat recovery and is suitable for installation in bathrooms and WC’s. Up to 77m³/h capacity (balanced airflow).
For installation in walls from 280mm to 500mm thick. Supplied with white ABS plastic external grille.
Raadpleeg de tab Downloads voor technische informatie
ESTIMATED RUNNING COSTS
Calculate estimated running costs for this product using the tool below.
For average costs*, leave the default values in place or enter your own figures in the boxes to recalculate.
Where a product has multi speeds, a typical installation has been used for the below calculations. *Running cost does not include the use of the heater on the heater model
Based on the inputted figures, estimated running costs would be:
Overview
The Vent-Axia HR100W range is designed for continuous operation providing up to 70% Heat Recovery. Effectively controlling internal relative humidity. The Vent-Axia HR100WH unit come complete with
integral humidity sensor and controls condensation and reduces mould.
Fresh pre-warmed air from the outside is continuously provided to the room with simultaneous extraction of stale, moist air.
An integral heat exchanger transfers heat from the outgoing stale air to the fresh air supply, raising the temperature of the fresh air and most importantly reducing the Relative Humidity of the supply air to the room.
The HR100WH has a two speed motor which provides for constant low rate
ventilation automatically switching to boost speed on rising humidity level of approximately 70% relative humidity at 20°C. This level can easily be adjusted by removing the front cover and heat exchanger to reveal the adjustment spindle.
Typical Installation
Extract Performance
m³/h
Intake Performance
m³/h
Watts
Sounds Levels
dB(A) @ 3m
Boost
Trickle
Boost
Trickle
Boost
Trickle
Boost
Trickle
73
43
69
38
31
12
30
20
HR100W units require a 240mm x 160mm hole. The unit should be fitted so that it slopes towards the outside (nominal 1°) to assist in-built condensate drainage.
The telescopic flange (adjustable to fit walls 220mm to 280mm thick) covers cutting marks and provides a surface for forming a seal with the external wall surface. An extension sleeve is available for thicker walls up to 500mm. (Stock Ref. 370419)
Maintenance
Filters should be replaced every six months or as conditions necessitate. Replacement filters can be purchased in packs of four. (Stock Ref. No. 37 03 78).The heat exchanger should be washed in warm soapy water every twelve months or as conditions necessitate. Access to the filter and heat exchanger is via two screws on the internal grille.
Power Consumption
Trickle
12.0W
Boost
31.0W
Technical
DIMENSIONS:
Weight: 4.85kg
A | B | C | D | E | F | G |
370 | 270 | 220-280 | 68 | 155 | 235 | 190 |
Models
With built-in Humidity Sensor A surface mounted heat recovery ventilation unit for use in bathrooms and toilets, meeting building regulations for this application. Up to 77m³/h capacity (balanced airflow).
Provides balanced ventilation with heat recovery and is suitable for installation in bathrooms and WC’s. Up to 77m³/h capacity (balanced airflow).
For installation in walls from 280mm to 500mm thick. Supplied with white ABS plastic external grille.