Roof Mounted Smoke Fans (CTH)
At a Glance:
Certified to EN12101-3 Standards.
Impellers manufactured in galvanised sheet steel.
Cowls manufactured from spun aluminium.
A full range of accessories is available to compliment the range.
Benefits:
Rated at 400°C/2h to EN12101-3
All metallic construction
Single & three phase options
Single & two speed motor options
Backward curved impellers
IP55 Protection
The CTH range of roof extract fans is available in horizontal discharge formats, and is suitable for many applications including:
- General ventilation - Industrial ventilation
- Industrial / Commercial kitchens
- Models:
- CTHB single phase
- CTHT three phase
- Air stream temperature - 40°C =120°C
- Complete metallic construction
Certified to EN12101-3 Standards.
Applications
Suitable for any smoke extract application where the fan must be roof mounted.
Impeller
Backward curved impellers manufactured in galvanised sheet steel (sizes 140-400) or double coated (cataphoresis + polyester) painted sheet steel (sizes 450-630). All models are dynamically balanced.
Bases
All base parts are manufactured from galvanised sheet steel.
Cowls
All cowls are manufactured from spun aluminium.
Motors
Asynchronous induction motors in die-cast aluminium:
- 230V 50Hz Single Phase
- 400V 50Hz Three Phase (230/400V under request)
- Sealed controllable in single and three phase for models 140-400.
- Sealed for life ball bearing assemblies.
In three phase voltage, the motors can be operated in connection at 380-415, which allows two speed operation of the fans.
General Performance Characteristics
The range consists of 11 unit sizes, covering an airflow range of up to 2.91m³/s. Available with 4, 6, 8 pole, single speed motors and 4/8, 6/12 pole, two speed motor options
Accessories
A full range of accessories is available to compliment this fan range including:
- Sealing frame - JMS
- Flat Roof Up-Stand - JBS
- Acoustic Up-Stand - JAA
- Back Draught Shutter - JCA
- S Flange - JBR
- Flexible Coupling - JPE
- Circular Duct Adaptor - JCC
- Support for individual curb mounted installation - CT/HCT
Typical Ordering Designation
Model
Motor
Poles
Dia.
CTHT
/
4
-
225
For full performance and selection, please contact our Project Team on 01293 455196 or info@vent-axia.com
DIMENSIONS:
Type | ØAH | BH | C | ØD* | E | ØF |
140 | 415 | 277 | 300 | 180 | 245 | 10 |
180 | 415 | 292 | 300 | 180 | 245 | 10 |
200 | 561 | 340 | 435 | 250 | 330 | 12 |
225 | 561 | 383 | 435 | 250 | 330 | 12 |
250 | 762 | 425 | 560 | 355 | 450 | 12 |
315 | 762 | 469 | 560 | 355 | 450 | 12 |
400 | 850 | 532 | 630 | 400 | 535 | 12 |
450 | 962 | 713 | 710 | 500 | 590 | 14 |
500 | 1214 | 824 | 905 | 630 | 750 | 14 |
560 | 1214 | 874 | 905 | 630 | 750 | 14 |
630 | 1336 | 1029 | 1100 | 710 | 845 | 14 |
Raadpleeg de tab Downloads voor technische informatie
ESTIMATED RUNNING COSTS
Calculate estimated running costs for this product using the tool below.
For average costs*, leave the default values in place or enter your own figures in the boxes to recalculate.
Where a product has multi speeds, a typical installation has been used for the below calculations. *Running cost does not include the use of the heater on the heater model
Based on the inputted figures, estimated running costs would be:
Overview
The CTH range of roof extract fans is available in horizontal discharge formats, and is suitable for many applications including:
- General ventilation - Industrial ventilation
- Industrial / Commercial kitchens
- Models:
- CTHB single phase
- CTHT three phase
- Air stream temperature - 40°C =120°C
- Complete metallic construction
Certified to EN12101-3 Standards.
Applications
Suitable for any smoke extract application where the fan must be roof mounted.
Impeller
Backward curved impellers manufactured in galvanised sheet steel (sizes 140-400) or double coated (cataphoresis + polyester) painted sheet steel (sizes 450-630). All models are dynamically balanced.
Bases
All base parts are manufactured from galvanised sheet steel.
Cowls
All cowls are manufactured from spun aluminium.
Motors
Asynchronous induction motors in die-cast aluminium:
- 230V 50Hz Single Phase
- 400V 50Hz Three Phase (230/400V under request)
- Sealed controllable in single and three phase for models 140-400.
- Sealed for life ball bearing assemblies.
In three phase voltage, the motors can be operated in connection at 380-415, which allows two speed operation of the fans.
General Performance Characteristics
The range consists of 11 unit sizes, covering an airflow range of up to 2.91m³/s. Available with 4, 6, 8 pole, single speed motors and 4/8, 6/12 pole, two speed motor options
Accessories
A full range of accessories is available to compliment this fan range including:
- Sealing frame - JMS
- Flat Roof Up-Stand - JBS
- Acoustic Up-Stand - JAA
- Back Draught Shutter - JCA
- S Flange - JBR
- Flexible Coupling - JPE
- Circular Duct Adaptor - JCC
- Support for individual curb mounted installation - CT/HCT
Typical Ordering Designation
Model
Motor
Poles
Dia.
CTHT
/
4
-
225
For full performance and selection, please contact our Project Team on 01293 455196 or info@vent-axia.com
Technical
DIMENSIONS:
Type | ØAH | BH | C | ØD* | E | ØF |
140 | 415 | 277 | 300 | 180 | 245 | 10 |
180 | 415 | 292 | 300 | 180 | 245 | 10 |
200 | 561 | 340 | 435 | 250 | 330 | 12 |
225 | 561 | 383 | 435 | 250 | 330 | 12 |
250 | 762 | 425 | 560 | 355 | 450 | 12 |
315 | 762 | 469 | 560 | 355 | 450 | 12 |
400 | 850 | 532 | 630 | 400 | 535 | 12 |
450 | 962 | 713 | 710 | 500 | 590 | 14 |
500 | 1214 | 824 | 905 | 630 | 750 | 14 |
560 | 1214 | 874 | 905 | 630 | 750 | 14 |
630 | 1336 | 1029 | 1100 | 710 | 845 | 14 |