Run & Standby Long Case Axial Fans (LCR)

This product range is now obsolete and no longer available from Vent-Axia. The information here is provided for reference only.

At a Glance:

12/24hr run and standby facility
Motors protected to IP55
Max. ambient temp 54°C
IP55 terminal box
Adjustable factory set impeller
Suitable for relative humidity levels up to 95% RH.
Manufacture controlled to BS EN ISO 9001
Performance tested to BS 848 Parts 1, 2 & ISO 5801
 

The Run and Standby Long Case Axial range of fans incorporate pre-adjusted impellers which provide a comprehensive range of duties offering high performance and pressure characteristics. Available in twelve sizes ranging from 315 to 1250mm diameter and performances up to 35m³/s (126,000m³/h) with pressure development up to 1000Pa. The casings are constructed from rolled steel plate complete with flanges and protected with a tough, galvanised finish.

Terminal Box
To IP55, protected against dust and water jets from any angle, allowing outside applications.

Motor / Impellers

The motors are specially selected for optimum performance and efficiency. Ball bearings are greased for life and allow the fan to be installed at any angle. Suitable for continuous operation in relative humidity up to 95%. Motors are protected to IP55 against dust and water jets complying with BS EN 60529. They have ribbed aluminium body castings for efficient cooling. Motor insulation is Class 'F' (from -35°C to +54°C). Star/delta starting is recommended for motor output above 4kW.

Motor Support Arms
Motors are mounted by means of specially designed support arms which act as an air straightener that helps minimise the turbulence and maximise performance, whilst ensuring quiet operation.

Impeller blades are clamped in a split cast aluminium hub, with a keywayed mild steel insert enabling positive locking of the impeller assembly to the motor shaft, this also allows factory adjustment of the pitch angle giving a wide selection of performances.

Electrical

Single phase 220-240V 50 Hz. Capacitor start and run. Three phase 380-415V 50Hz. Protection of the motor must be provided by an overload current sensing device (eg. D.O.L Starter or Star/Delta starter where appropriate) or the guarantee will be invalidated.

DIMENSIONS:

Size A B (MAX) C D E F G
LCR315 315 840 355 385 8 10 224
LCR350 355 840 395 425 8 10 250
LCR400 400 870 450 480 8 12 280
LCR450 450 870 500 530 8 12 315
LCR500 500 1130 560 590 12 12 315
LCR560 560 1130 620 650 12 12 355
LCR630 630 1130 690 720 12 12 400
LCR710 710 940 770 800 16 12 410
LCR800 800 1130 860 890 16 12 450
LCR900 900 1400 970 1038 16 14 500
LCR1000 1000 1580 1070 1138 16 14 555
LCR1250 1250 2200 1320 1390 20 15 868

PDF DOWNLOADS:

 

Raadpleeg de tab Downloads voor technische informatie

 

 

ESTIMATED RUNNING COSTS

Calculate estimated running costs for this product using the tool below.
For average costs*, leave the default values in place or enter your own figures in the boxes to recalculate.
Where a product has multi speeds, a typical installation has been used for the below calculations. *Running cost does not include the use of the heater on the heater model


pence
(Your current electricity cost in pence per hour. This will be listed on your electric bill)
hours
(The average number of hours per day fan to run in Trickle mode)
hours
(The average number of hours per day fan to run in Boost mode)

Based on the inputted figures, estimated running costs would be:

Overview

The Run and Standby Long Case Axial range of fans incorporate pre-adjusted impellers which provide a comprehensive range of duties offering high performance and pressure characteristics. Available in twelve sizes ranging from 315 to 1250mm diameter and performances up to 35m³/s (126,000m³/h) with pressure development up to 1000Pa. The casings are constructed from rolled steel plate complete with flanges and protected with a tough, galvanised finish.

Terminal Box
To IP55, protected against dust and water jets from any angle, allowing outside applications.

Motor / Impellers

The motors are specially selected for optimum performance and efficiency. Ball bearings are greased for life and allow the fan to be installed at any angle. Suitable for continuous operation in relative humidity up to 95%. Motors are protected to IP55 against dust and water jets complying with BS EN 60529. They have ribbed aluminium body castings for efficient cooling. Motor insulation is Class 'F' (from -35°C to +54°C). Star/delta starting is recommended for motor output above 4kW.

Motor Support Arms
Motors are mounted by means of specially designed support arms which act as an air straightener that helps minimise the turbulence and maximise performance, whilst ensuring quiet operation.

Impeller blades are clamped in a split cast aluminium hub, with a keywayed mild steel insert enabling positive locking of the impeller assembly to the motor shaft, this also allows factory adjustment of the pitch angle giving a wide selection of performances.

Electrical

Single phase 220-240V 50 Hz. Capacitor start and run. Three phase 380-415V 50Hz. Protection of the motor must be provided by an overload current sensing device (eg. D.O.L Starter or Star/Delta starter where appropriate) or the guarantee will be invalidated.

Technical

DIMENSIONS:

Size A B (MAX) C D E F G
LCR315 315 840 355 385 8 10 224
LCR350 355 840 395 425 8 10 250
LCR400 400 870 450 480 8 12 280
LCR450 450 870 500 530 8 12 315
LCR500 500 1130 560 590 12 12 315
LCR560 560 1130 620 650 12 12 355
LCR630 630 1130 690 720 12 12 400
LCR710 710 940 770 800 16 12 410
LCR800 800 1130 860 890 16 12 450
LCR900 900 1400 970 1038 16 14 500
LCR1000 1000 1580 1070 1138 16 14 555
LCR1250 1250 2200 1320 1390 20 15 868

Downloads