eViking Air Handling Unit Range
A+ Energy Class design
Heat recovery efficiencies >= 80%
Motor options, EFF1(IE2) or EC/DC
Minimised pressure drop of inbuilt assemblies
Casing air tightness - L2
Thermal Insulation standard T3
Optimised footprint
The new eViking range of Air Handling units has been designed to meet the latest European Regulations, whilst ensuring the highest energy efficiency is available.
Spanning a duty envelope of 3.47m³/s to 16.13m³/s eViking Air Handling units are available in 8 configurations of width & height.
eViking features not only offers significantly better performance and technical parameters but also greater reliability and a reduced footprint.
eViking Air handling units have a unique & new patented Laminated panel construction which gives a high thermal and acoustic performance, with simplified manufacturing process.
Improved accessibility to maintenance sections is provided with inspection doors and panels and variability of connections enables specifiers to combine the side of pipework connections & service access enabling optimisation of the plant room space & ensure easy access for maintenance.
Connection of sections is simple providing fast and easy installation, and the clean inside surface to the unit, allows easy cleaning.
All internal electrical devices can be terminated on the external casing with terminal boxes, or internally to simplifying installation and reduce installation costs.
Units are suitable for internal or external application with a comprehensive range of options on internal and external material finishes to meet the most demanding project specifications.
Design request
To request an eViking design & quotation, please download the design request form on the right of this page or click here
PRODUCT SPECIFICATION:
- Fans - Direct or Belt Drive
- High efficiency Motor options – IE2 or EC/DC
- Dampers, Mixing Boxes
- Panel Filters, Bag Filters
- Heating Coils (LPHW, Electric)
- Cooling Coils (CHW & DX)
- Humidification - Steam or Adiabatic
- Heat Recovery - Plate or Rotary
- Attenuators
- Control options - Standard or WebClima
eViking Air Handling units are available in a variety of configurations, suitable for both internal and external applications and to meet project requirements. Also offered are a wide selection of both internal & external case materials and finishes to suit the most demanding of applications.
Raadpleeg de tab Downloads voor technische informatie
ESTIMATED RUNNING COSTS
Calculate estimated running costs for this product using the tool below.
For average costs*, leave the default values in place or enter your own figures in the boxes to recalculate.
Where a product has multi speeds, a typical installation has been used for the below calculations. *Running cost does not include the use of the heater on the heater model
Based on the inputted figures, estimated running costs would be:
Overview
The new eViking range of Air Handling units has been designed to meet the latest European Regulations, whilst ensuring the highest energy efficiency is available.
Spanning a duty envelope of 3.47m³/s to 16.13m³/s eViking Air Handling units are available in 8 configurations of width & height.
eViking features not only offers significantly better performance and technical parameters but also greater reliability and a reduced footprint.
eViking Air handling units have a unique & new patented Laminated panel construction which gives a high thermal and acoustic performance, with simplified manufacturing process.
Improved accessibility to maintenance sections is provided with inspection doors and panels and variability of connections enables specifiers to combine the side of pipework connections & service access enabling optimisation of the plant room space & ensure easy access for maintenance.
Connection of sections is simple providing fast and easy installation, and the clean inside surface to the unit, allows easy cleaning.
All internal electrical devices can be terminated on the external casing with terminal boxes, or internally to simplifying installation and reduce installation costs.
Units are suitable for internal or external application with a comprehensive range of options on internal and external material finishes to meet the most demanding project specifications.
Design request
To request an eViking design & quotation, please download the design request form on the right of this page or click here
Technical
PRODUCT SPECIFICATION:
- Fans - Direct or Belt Drive
- High efficiency Motor options – IE2 or EC/DC
- Dampers, Mixing Boxes
- Panel Filters, Bag Filters
- Heating Coils (LPHW, Electric)
- Cooling Coils (CHW & DX)
- Humidification - Steam or Adiabatic
- Heat Recovery - Plate or Rotary
- Attenuators
- Control options - Standard or WebClima
eViking Air Handling units are available in a variety of configurations, suitable for both internal and external applications and to meet project requirements. Also offered are a wide selection of both internal & external case materials and finishes to suit the most demanding of applications.