Access Rectangular In-Line fans - ARH
At a Glance:
Specifically designed with the latest COSHH (Control of Substances Hazardous to Health) regulations in mind.
Has been developed for commercial and industrial applications with the emphasis on fast installation and reliable performance.
Manufacture controlled to BS EN ISO 9001.
Performance tested to BS 848 Parts 1 & 2.
2 Year Guarantee
FAQ's Answered:
Motor insulation Class B
Standard Thermal Overload Protection
Access panel for ease of maintenance
MEZ flanging
Backward curved centrifugal impeller
The ACCESS range of rectangular backward curved in-line fans have been specifically designed with the latest COSHH (Control of Substances Hazardous to Health) regulations in mind.
These regulations make it a requirement for employers to provide effective methods to control exposure to certain hazardous materials and substances in the work place utilising general or local exhaust ventilation systems. The regulations also require that the system installed be inspected and maintained on a regular and documented basis.
ACCESS has been developed for commercial and industrial applications with the emphasis on fast installation, reliable performance and access for inspection. It features a new generation of backward curved fans specially selected for their performance and non overloading characteristics.
This range of rectangular fans are available with matched accessories for complete ventilation systems in a variety of ducted applications. The innovative and compact design of the galvanised steel casing, backward curved impeller and motor unit ensures that the Access model occupies no more space than ordinary forward curved units.
An access panel on all models comes complete with the motor and impeller assembly mounted on it making maintenance a swift and simple procedure.
Motors / Impellers
The range is powered by a proven external rotor motor and impeller assembly dynamically balanced for quiet, vibration free performance. Motors are rated IP44 according to BS EN 60529. Bearings are greased for life and are designed to run at any angle. Motor insulation is Class 'B'. 100 to 315 Ø operating temperatures 50°C; 355 to 710 dia 40°C.
Manufacture of the motor impellers, casings and assembly are all controlled to BS EN ISO 9001 standards. The motor/impeller assemblies are dynamically balanced to VDI 2060.
Electrical
Single phase 220-240V 50 Hz. Capacitor start and run. The capacitors are located in the terminal box where possible. Three phase 380-415V 50 Hz. The terminal box on models 355 to 710 are protected to IP54 according to BS EN 60529. All motors are fitted with Standard Thermal Overload Protection (S.T.O.P.), which should be wired into all controller circuits and into starter contactors. Models are available with 2, 4, 6 and 8 pole motors.
Performance
Tested to BS 848 Parts 1 & 2. Published dB(A) figures are free field sound pressure levels at 3m with spherical propagation at a reference level of 2 x 10–5Pa (20 micro-Pascals). The inlet and outlet sound power level spectra figures are dB with a reference of 10–12 Watts (1 pico-watt).
Accessories
Rectangular flexible connections, attenuators and bag filter cassettes.
Click here for technical information, within our Online Product Selector. After, select your required fan model from the list to display Performance, Sound, Dimensions and Electrical Data.
Raadpleeg de tab Downloads voor technische informatie
ESTIMATED RUNNING COSTS
Calculate estimated running costs for this product using the tool below.
For average costs*, leave the default values in place or enter your own figures in the boxes to recalculate.
Where a product has multi speeds, a typical installation has been used for the below calculations. *Running cost does not include the use of the heater on the heater model
Based on the inputted figures, estimated running costs would be:
Overview
The ACCESS range of rectangular backward curved in-line fans have been specifically designed with the latest COSHH (Control of Substances Hazardous to Health) regulations in mind.
These regulations make it a requirement for employers to provide effective methods to control exposure to certain hazardous materials and substances in the work place utilising general or local exhaust ventilation systems. The regulations also require that the system installed be inspected and maintained on a regular and documented basis.
ACCESS has been developed for commercial and industrial applications with the emphasis on fast installation, reliable performance and access for inspection. It features a new generation of backward curved fans specially selected for their performance and non overloading characteristics.
This range of rectangular fans are available with matched accessories for complete ventilation systems in a variety of ducted applications. The innovative and compact design of the galvanised steel casing, backward curved impeller and motor unit ensures that the Access model occupies no more space than ordinary forward curved units.
An access panel on all models comes complete with the motor and impeller assembly mounted on it making maintenance a swift and simple procedure.
Motors / Impellers
The range is powered by a proven external rotor motor and impeller assembly dynamically balanced for quiet, vibration free performance. Motors are rated IP44 according to BS EN 60529. Bearings are greased for life and are designed to run at any angle. Motor insulation is Class 'B'. 100 to 315 Ø operating temperatures 50°C; 355 to 710 dia 40°C.
Manufacture of the motor impellers, casings and assembly are all controlled to BS EN ISO 9001 standards. The motor/impeller assemblies are dynamically balanced to VDI 2060.
Electrical
Single phase 220-240V 50 Hz. Capacitor start and run. The capacitors are located in the terminal box where possible. Three phase 380-415V 50 Hz. The terminal box on models 355 to 710 are protected to IP54 according to BS EN 60529. All motors are fitted with Standard Thermal Overload Protection (S.T.O.P.), which should be wired into all controller circuits and into starter contactors. Models are available with 2, 4, 6 and 8 pole motors.
Performance
Tested to BS 848 Parts 1 & 2. Published dB(A) figures are free field sound pressure levels at 3m with spherical propagation at a reference level of 2 x 10–5Pa (20 micro-Pascals). The inlet and outlet sound power level spectra figures are dB with a reference of 10–12 Watts (1 pico-watt).
Accessories
Rectangular flexible connections, attenuators and bag filter cassettes.
Technical
Click here for technical information, within our Online Product Selector. After, select your required fan model from the list to display Performance, Sound, Dimensions and Electrical Data.