Slimpak (SLPT) - In-Line Twin Duct Fans
• Motor Insulation Class B, protected to IP44
• All units suitable for speed control
• Quality Assurance to BS EN ISO 9001:1994
• Performance tested to BS848 Part 1 1980
• Units suitable as a run & standby extract fan or simultaneously running fan
The Slimpak range of streamline twin fan units, which have been designed to allow the unit to be installed as a Run & Standby extract fan or alternatively running both fans simultaneously for optimum performance, offering total flexibility.
Slimpak housings are manufactured from prime quality galvanised sheet steel with circular inlet and outlet spigot connections. To ensure minimum noise levels the units casing is treated with an acoustic lining, Class O rated which offers self extinguishing, zero burn rate, resists ignition and no toxic fume properties.
Each unit incorporates a back draught shutter to prevent air recirculation via the standby fan and to ensure easy access for cleaning and maintenance purposes a full sized access panel is provided to both fans.
Designed and developed to provide one of the most powerful and compact twins in the market, available in three sizes 200, 250 and 315mm dia, with extract performance ranging from 0.116m³/s up to 0.400m³/s (417m³/h to 1,440m³/h), with pressure characteristics of up 550Pa.
Motors
At the heart of the range is a proven 230V/1/50Hz external rotor motor and backward curved impeller assembly. The assembly is dynamically balanced to ISO 1940. Motors are rated to IP44 according to BS EN 60529. Ball bearings are greased for life and allow the fan to run at any angle. Insulation is Class 'B' (from -15°C to +40°C).
All Acoustic fans are suitable for speed control, an Auto Transformer is recommended to ensure minimum noise levels during speed control so eliminating any possibility of motor harmonic noise.
Performance and Sound
Tested to BS 848 Parts 1 & 2. Published dB(A) figures are free field sound pressure levels at 3m with spherical propagation at a reference level of 2 x 10-5 Pa (20 micro-Pascal). The inlet, outlet and breakout sound power level spectra figures are dB with a reference of 10-12 Watts (1 pico-watt).
Quality Assurance
Design and manufacture shall be in accordance with BS EN ISO 9001:1994.
DIMENSIONS:
Duct Dia. | Stock Ref. No. | L | W | H | ØD | X | Weight Kg |
200 | SLPT200 | 760 | 490 | 235 | 200 | 205 | 20 |
250 | SLPT250 | 865 | 590 | 285 | 250 | 233 | 32 |
315 | SLPT315 | 955 | 650 | 350 | 315 | 240 | 39 |
Please click here for the latest product alternative
The ITC model provides automatic changeover on fan failure as well as enabling a manual selection of either fan for duty sharing or test purposes. (BMS compatible via volt free contacts). This controller must have a permanent live supply. Any On/Off switching must be via the sensor connections S1 and SG terminals.
The ITC-DS model (Duty sharing). Incorporates a timing mechanism which operates alternate fans on 12 or 24 hour intervals, thus ensuring the extended life of the fan bearings. The controller also provides automatic changeover on fan failure along with the facility for manual selection of either fan. (BMS compatible via volt free contacts). This controller must have a permanent live supply. Any On/Off switching must be via the sensor connections S1 and SG terminals
The RSC multi-speed control system offers 2 speed fan versatility eg. Energy Management for night-time setback. Can be used in conjunction with Vent-Axia ITC, ITC-DS controllers using 5 step auto-transformer speed controllers for speed selection. Uses 24V output from ITC controller. Dimensions: 86mm x 178mm x 100mm (Width x Height x Depth)
Raadpleeg de tab Downloads voor technische informatie
ESTIMATED RUNNING COSTS
Calculate estimated running costs for this product using the tool below.
For average costs*, leave the default values in place or enter your own figures in the boxes to recalculate.
Where a product has multi speeds, a typical installation has been used for the below calculations. *Running cost does not include the use of the heater on the heater model
Based on the inputted figures, estimated running costs would be:
Overview
The Slimpak range of streamline twin fan units, which have been designed to allow the unit to be installed as a Run & Standby extract fan or alternatively running both fans simultaneously for optimum performance, offering total flexibility.
Slimpak housings are manufactured from prime quality galvanised sheet steel with circular inlet and outlet spigot connections. To ensure minimum noise levels the units casing is treated with an acoustic lining, Class O rated which offers self extinguishing, zero burn rate, resists ignition and no toxic fume properties.
Each unit incorporates a back draught shutter to prevent air recirculation via the standby fan and to ensure easy access for cleaning and maintenance purposes a full sized access panel is provided to both fans.
Designed and developed to provide one of the most powerful and compact twins in the market, available in three sizes 200, 250 and 315mm dia, with extract performance ranging from 0.116m³/s up to 0.400m³/s (417m³/h to 1,440m³/h), with pressure characteristics of up 550Pa.
Motors
At the heart of the range is a proven 230V/1/50Hz external rotor motor and backward curved impeller assembly. The assembly is dynamically balanced to ISO 1940. Motors are rated to IP44 according to BS EN 60529. Ball bearings are greased for life and allow the fan to run at any angle. Insulation is Class 'B' (from -15°C to +40°C).
All Acoustic fans are suitable for speed control, an Auto Transformer is recommended to ensure minimum noise levels during speed control so eliminating any possibility of motor harmonic noise.
Performance and Sound
Tested to BS 848 Parts 1 & 2. Published dB(A) figures are free field sound pressure levels at 3m with spherical propagation at a reference level of 2 x 10-5 Pa (20 micro-Pascal). The inlet, outlet and breakout sound power level spectra figures are dB with a reference of 10-12 Watts (1 pico-watt).
Quality Assurance
Design and manufacture shall be in accordance with BS EN ISO 9001:1994.
Technical
DIMENSIONS:
Duct Dia. | Stock Ref. No. | L | W | H | ØD | X | Weight Kg |
200 | SLPT200 | 760 | 490 | 235 | 200 | 205 | 20 |
250 | SLPT250 | 865 | 590 | 285 | 250 | 233 | 32 |
315 | SLPT315 | 955 | 650 | 350 | 315 | 240 | 39 |
Accessories
Please click here for the latest product alternative
The ITC model provides automatic changeover on fan failure as well as enabling a manual selection of either fan for duty sharing or test purposes. (BMS compatible via volt free contacts). This controller must have a permanent live supply. Any On/Off switching must be via the sensor connections S1 and SG terminals.
The ITC-DS model (Duty sharing). Incorporates a timing mechanism which operates alternate fans on 12 or 24 hour intervals, thus ensuring the extended life of the fan bearings. The controller also provides automatic changeover on fan failure along with the facility for manual selection of either fan. (BMS compatible via volt free contacts). This controller must have a permanent live supply. Any On/Off switching must be via the sensor connections S1 and SG terminals
The RSC multi-speed control system offers 2 speed fan versatility eg. Energy Management for night-time setback. Can be used in conjunction with Vent-Axia ITC, ITC-DS controllers using 5 step auto-transformer speed controllers for speed selection. Uses 24V output from ITC controller. Dimensions: 86mm x 178mm x 100mm (Width x Height x Depth)