Galaxy Roof Mounting Belt Driven Twin Fans - GRB

This product range is now obsolete and no longer available from Vent-Axia. The information here is provided for reference only.

At a Glance:
• Roof mounting, fully weatherproofed belt driven, low silhouette twin fan
• High quality mill finished aluminium casing
• Anodised aluminium discharge louvre
• Optional inlet spigot position
• Pre-wired IP65 Service Isolator
• Motor Insulation Class ‘F’
• Maximum operating temperature 40°C
• Manufacture controlled to BS EN ISO 9001
• Performance tested to BS 848 Part 1 & 2
• 2 Year Guarantee

The GRB Galaxy Roof Mounting Belt Driven Twin fan range represents the latest development from Vent-Axia in high performance, run and standby twin fan. Designed to be controlled inconjunction with Vent-Axia Trakmaster twin fan controller range, the total package offers the end user flexibility when interfaced with or without a (BMS) Building Management Systems, such as: manual selection; 12/24hr auto changeover ensuring the extended life of the fan and motor; night setback during low levels of occupancy, for energy management control during 24hr extraction.

The unit casing is manufactured from mill finished aluminium fitted with discharge aluminium weather louvre with bird mesh as standard. Assembly is controlled to BS EN ISO 9001.

Individual gravity return shutters are fitted as standard to prevent air recirculation through the standby fan or the system during shut down periods. Galaxy Roof Mounting Fans are only suitable for horizontal mounting. When installed on a shallow pitch roof a special upstand will needed to compensate for the angular difference – to be manufactured by others.

To meet COSHH requirements, double pole service isolator switches are fitted and pre-wired from the fans and mounted to the outer casing to reduce installation time and cost. Access to the fan section is via an easily removed top access panel for cleaning and maintenance during shut down periods.

The Galaxy range is available in four models with extract performance ranging from 0.02m³/s up to 2.5m³/s (720m³/h to 9000m³/h), with pressure characteristics of up 400Pa.All models
are supplied with inlet spigots on the underside of the unit casing and a discharge anodized aluminium weather louvre.

Fan / Motor Assembly

Galaxy GRB belt driven fans are double inlet double width, forward curved centrifugal fans belt driven by totally enclosed fan ventilated motors, wound to suit 220-240V/1/50HZ or 380-415V/1/50Hz electrical supply. Protected to IP54, against dust and water jets complying with BS EN 60529.

Motor insulation is Class F as a minimum, suitable for operating temperatures up to +40°C. The fans and motors are mounted on a steel frame, with anti-vibration mounts between the frame and casing and a flexible connection between the fan scroll and fan plate, minimising vibration. All belt driven Galaxy units are supplied with metric pulleys to ISO 4183 and wedge belts to ISO 4184 and DIN 7753.

Electrical

All Motors are available in either, single phase 220-240V 50 Hz capacitor start and run. Three phase 380V-415V 50Hz. The service isolator is supplied with all models with 20mm and PG11 entry, protected against dust and water jets from any angle.

Performance
The GRB fan performances is tested in accordance with test BS848 Part 1.

Sound Levels
The fan sound levels are measured in a reverberant chamber in accordance with BS848 Part 2. Published dB(A) figures are free field sound pressure levels at 3m with spherical propagation at a reference level of 2 x 10–5Pa (20 micro-Pascal). The inlet and outlet sound power level spectra figures are dB with a reference of 10–sup>12Watts (1 pico-watt). To ensure minimum noise levels during speed control, an auto transformer speed control is recommended.

Quality Assurance
Design and manufacture are in accordance with the standard for quality management system BS EN ISO 9001.

DIMENSIONS:

Unit A B C D E F G H J Weight kg
GRB1 500 900 1100 900 500 250 247 100 900 90
GRB2 600 1150 1175 1120 762 305 150 27.5 1120 120
GRB3 700 1450 1450 1450 900 400 150 - 1450 195
GRB4 800 1550 1450 1550 1000 450 150 - 1450 215
 
Image of Trackmaster Twin Fan Controller (ITC)
Trackmaster Twin Fan Controller (ITC)

 

Please click here for the latest product alternative

The ITC model provides automatic changeover on fan failure as well as enabling a manual selection of either fan for duty sharing or test purposes. (BMS compatible via volt free contacts). This controller must have a permanent live supply. Any On/Off switching must be via the sensor connections S1 and SG terminals.

Stock Ref. No: 10314200
This Model no longer available
Image of Trackmaster Twin Fan Controller (ITC-DS)
Trackmaster Twin Fan Controller (ITC-DS)

The ITC-DS model (Duty sharing). Incorporates a timing mechanism which operates alternate fans on 12 or 24 hour intervals, thus ensuring the extended life of the fan bearings. The controller also provides automatic changeover on fan failure along with the facility for manual selection of either fan. (BMS compatible via volt free contacts). This controller must have a permanent live supply. Any On/Off switching must be via the sensor connections S1 and SG terminals

Stock Ref. No: 10314210
Price £577.31 (excl VAT)
Image of RSC - Remote Setback Control
RSC - Remote Setback Control

The RSC multi-speed control system offers 2 speed fan versatility eg. Energy Management for night-time setback. Can be used in conjunction with Vent-Axia ITC, ITC-DS controllers using 5 step auto-transformer speed controllers for speed selection. Uses 24V output from ITC controller. Dimensions: 86mm x 178mm x 100mm (Width x Height x Depth)

Stock Ref. No: 10314230A
(Please call 0344 856 0590 0344 856 0590 for further availability information)
Image of Remote Visual Indicator (RVC)
Remote Visual Indicator (RVC)
Wired in conjunction with either an ITC or ITC-DS controller the RVC can be located up to 100m away using low cost ELV wiring. The compact, single gang RVC ELV (Extra Low Voltage) remote visual controller indicates status of Fan 1 and Fan 2 with status/warning lights. Push button allows Fan 1 and Fan 2 with standby (Off) to be selected.
Stock Ref. No: 10314220
Price £164.59 (excl VAT)
(Please call 0344 856 0590 0344 856 0590 for further availability information)

 

Raadpleeg de tab Downloads voor technische informatie

 

 

ESTIMATED RUNNING COSTS

Calculate estimated running costs for this product using the tool below.
For average costs*, leave the default values in place or enter your own figures in the boxes to recalculate.
Where a product has multi speeds, a typical installation has been used for the below calculations. *Running cost does not include the use of the heater on the heater model


pence
(Your current electricity cost in pence per hour. This will be listed on your electric bill)
hours
(The average number of hours per day fan to run in Trickle mode)
hours
(The average number of hours per day fan to run in Boost mode)

Based on the inputted figures, estimated running costs would be:

£0.00 Per Day
£0.00 Per Month
£0.00 Per Year

Overview

The GRB Galaxy Roof Mounting Belt Driven Twin fan range represents the latest development from Vent-Axia in high performance, run and standby twin fan. Designed to be controlled inconjunction with Vent-Axia Trakmaster twin fan controller range, the total package offers the end user flexibility when interfaced with or without a (BMS) Building Management Systems, such as: manual selection; 12/24hr auto changeover ensuring the extended life of the fan and motor; night setback during low levels of occupancy, for energy management control during 24hr extraction.

The unit casing is manufactured from mill finished aluminium fitted with discharge aluminium weather louvre with bird mesh as standard. Assembly is controlled to BS EN ISO 9001.

Individual gravity return shutters are fitted as standard to prevent air recirculation through the standby fan or the system during shut down periods. Galaxy Roof Mounting Fans are only suitable for horizontal mounting. When installed on a shallow pitch roof a special upstand will needed to compensate for the angular difference – to be manufactured by others.

To meet COSHH requirements, double pole service isolator switches are fitted and pre-wired from the fans and mounted to the outer casing to reduce installation time and cost. Access to the fan section is via an easily removed top access panel for cleaning and maintenance during shut down periods.

The Galaxy range is available in four models with extract performance ranging from 0.02m³/s up to 2.5m³/s (720m³/h to 9000m³/h), with pressure characteristics of up 400Pa.All models
are supplied with inlet spigots on the underside of the unit casing and a discharge anodized aluminium weather louvre.

Fan / Motor Assembly

Galaxy GRB belt driven fans are double inlet double width, forward curved centrifugal fans belt driven by totally enclosed fan ventilated motors, wound to suit 220-240V/1/50HZ or 380-415V/1/50Hz electrical supply. Protected to IP54, against dust and water jets complying with BS EN 60529.

Motor insulation is Class F as a minimum, suitable for operating temperatures up to +40°C. The fans and motors are mounted on a steel frame, with anti-vibration mounts between the frame and casing and a flexible connection between the fan scroll and fan plate, minimising vibration. All belt driven Galaxy units are supplied with metric pulleys to ISO 4183 and wedge belts to ISO 4184 and DIN 7753.

Electrical

All Motors are available in either, single phase 220-240V 50 Hz capacitor start and run. Three phase 380V-415V 50Hz. The service isolator is supplied with all models with 20mm and PG11 entry, protected against dust and water jets from any angle.

Performance
The GRB fan performances is tested in accordance with test BS848 Part 1.

Sound Levels
The fan sound levels are measured in a reverberant chamber in accordance with BS848 Part 2. Published dB(A) figures are free field sound pressure levels at 3m with spherical propagation at a reference level of 2 x 10–5Pa (20 micro-Pascal). The inlet and outlet sound power level spectra figures are dB with a reference of 10–sup>12Watts (1 pico-watt). To ensure minimum noise levels during speed control, an auto transformer speed control is recommended.

Quality Assurance
Design and manufacture are in accordance with the standard for quality management system BS EN ISO 9001.

Technical

DIMENSIONS:

Unit A B C D E F G H J Weight kg
GRB1 500 900 1100 900 500 250 247 100 900 90
GRB2 600 1150 1175 1120 762 305 150 27.5 1120 120
GRB3 700 1450 1450 1450 900 400 150 - 1450 195
GRB4 800 1550 1450 1550 1000 450 150 - 1450 215
 

Accessories

Image of Trackmaster Twin Fan Controller (ITC)
Trackmaster Twin Fan Controller (ITC)

 

Please click here for the latest product alternative

The ITC model provides automatic changeover on fan failure as well as enabling a manual selection of either fan for duty sharing or test purposes. (BMS compatible via volt free contacts). This controller must have a permanent live supply. Any On/Off switching must be via the sensor connections S1 and SG terminals.

Stock Ref. No: 10314200
This Model no longer available
Image of Trackmaster Twin Fan Controller (ITC-DS)
Trackmaster Twin Fan Controller (ITC-DS)

The ITC-DS model (Duty sharing). Incorporates a timing mechanism which operates alternate fans on 12 or 24 hour intervals, thus ensuring the extended life of the fan bearings. The controller also provides automatic changeover on fan failure along with the facility for manual selection of either fan. (BMS compatible via volt free contacts). This controller must have a permanent live supply. Any On/Off switching must be via the sensor connections S1 and SG terminals

Stock Ref. No: 10314210
Price £577.31 (excl VAT)
Image of RSC - Remote Setback Control
RSC - Remote Setback Control

The RSC multi-speed control system offers 2 speed fan versatility eg. Energy Management for night-time setback. Can be used in conjunction with Vent-Axia ITC, ITC-DS controllers using 5 step auto-transformer speed controllers for speed selection. Uses 24V output from ITC controller. Dimensions: 86mm x 178mm x 100mm (Width x Height x Depth)

Stock Ref. No: 10314230A
(Please call 0344 856 0590 0344 856 0590 for further availability information)
Image of Remote Visual Indicator (RVC)
Remote Visual Indicator (RVC)
Wired in conjunction with either an ITC or ITC-DS controller the RVC can be located up to 100m away using low cost ELV wiring. The compact, single gang RVC ELV (Extra Low Voltage) remote visual controller indicates status of Fan 1 and Fan 2 with status/warning lights. Push button allows Fan 1 and Fan 2 with standby (Off) to be selected.
Stock Ref. No: 10314220
Price £164.59 (excl VAT)
(Please call 0344 856 0590 0344 856 0590 for further availability information)

Downloads