Long Case Axial fans - LC

This product range is now obsolete and no longer available from Vent-Axia. The information here is provided for reference only.

At a Glance:

Incorporates manually adjustable pitch impellers which provide a range of duties.
The casing is constructed from rolled steel plate complete with flanges and protected with a tough galvanised finish.
The motors are specially selected for optimum performance and efficiency.
All models are supplied with an EC Declaration of Conformity as defined by the EC Council Directive on Machinery 89/392/EEC.
Adjustable factory set die cast aluminium impeller.

FAQ's Answered:

Motors protected to IP55
Motor Insulation Class 'F'
Maximum ambient temp 55°C
Speed controllable via transformer inverter
Suitable for relative humidity levels up to 95% R.H.
Manufacture controlled to BS EN ISO 9001
Performance tested to BS 848 Parts 1 & 2 and ISO 5801
2 year guarantee

The Long Case Axial range of fans incorporates manually adjustable pitch impellers which provide a comprehensive range of duties offering high performance and pressure characteristics.

Available in twelve sizes ranging from 315 to 1250mm diameter and performances from 0.24m3/s to 38m3/s (864m3/h to 136,800m3/h) with pressure development up to 1250Pa. The casing is constructed from rolled steel plate complete with flanges and protected with a tough, galvanised finish.

The Long Case Axial range has a range of accessories available which include: Axial Ancillary Pack, Cased Axial Attenuator, Mounting Feet, Wire Inlet Guard, Coupling Flange & Speed Controllers.

Motor / Impellers

The motors are specially selected for optimum performance and efficiency. Ball bearings are greased for life and allow the fan to be installed at any angle. Suitable for continuous operation in relative humidity up to 95%. Motors are protected to IP55 against dust and water jets complying with BS EN 60529. They have ribbed aluminium body castings for efficient cooling. Motor insulation is Class 'F' (from -35°C to +54°C). Star/delta starting is recommended for motor output above 4kW.

Impeller blades are clamped in a split cast aluminium hub, with a keywayed mild steel insert enabling positive locking of the impeller assembly to the motor shaft, this also allows manual adjustment of the pitch angle giving a wide selection of performance details.

Terminal Box
To IP55, protected against dust and water jets from any angle, allowing outside applications.

Electrical

Single phase 220-240V 50 Hz capacitor start and run. Three phase 380-415V 50Hz. Protection of the motor must be provided by an overload current sensing device (eg. D.O.L Starter or Star/Delta starter where appropriate) or the guarantee will be invalidated. All models are available with 4 pole motors for 315 up to 1250mm with additional 2 pole motors available from 315 up to 630mm.

Motors protected to IP55 against dust & water jets.
Composite cast aluminium axial impellers
Terminal box protected to IP55

Selection Guide

All stocked fans have the impellers set at the maximum pitch angle relative to the motor power of the fan unit and are available for adjustment below the pre-set pitch angle (adjustment down in 2° intervals). These units will be factory set before despatch.

DIMENSIONS:

No. A B C D E F G
LC31 A2/1&3/ 8-32 315 420 355 385 8 10 224
LC31 A4/1&3/ 8-32 315 420 355 385 8 10 224
LC35 A2/1&3/ 8-32 355 420 395 425 8 10 250
LC35 A4/1&3/ 8-32 355 420 395 425 8 10 250
LC40 A2/1&3/ 8-28 400 435 450 480 8 12 280
LC40 A2/1&3/ 8-32 400 435 450 480 8 12 280
LC45 A2/3/ 8-24 450 435 500 530 8 12 315
LC45 A4/1&3/ 8-32 450 435 500 530 8 12 315
LC50 A2/3/ 8-16 500 470 560 590 12 12 315
LC50 A2/3/ 8-26 500 565 560 590 12 12 315
LC50 A4/1&3/ 8-28 500 470 560 590 12 12 315
LC56 A2/3/ 8-18 560 470 620 650 12 12 355
LC56 A2/3/ 20-24 560 565 620 650 12 12 355
LC56 A4/1&3/ 8-26 560 470 620 650 12 12 355
LC63 A2/3/ 8-16 630 565 690 720 12 12 400
LC63 A4/1/ 8-22 630 470 690 720 12 12 400
LC63 A4/3/ 8-30 630 470 690 720 12 12 400
LC71 A4/3/ 8-30 710 470 770 800 16 12 410
LC80 A4/3/ 8-18 800 470 860 890 16 12 450
LC80 A4/3/ 20-28 800 565 860 890 16 12 450
LC90 A4/3/ 8-18 900 565 970 1038 16 14 500
LC90 A4/3/ 20-32 900 700 970 1038 16 14 500
LC100 A4/3/ 8-12 1000 565 1070 1138 16 14 555
LC100 A4/3/ 14-22 1000 700 1070 1138 16 14 555
LC100 A4/3/ 24-28 1000 790 1070 1138 16 14 555
LC125 A4/3/ 8-14 1250 950 1320 1390 20 15 868
LC125 A4/3/ 16-24 1250 1100 1320 1390 20 15 868

 

Raadpleeg de tab Downloads voor technische informatie

 

 

ESTIMATED RUNNING COSTS

Calculate estimated running costs for this product using the tool below.
For average costs*, leave the default values in place or enter your own figures in the boxes to recalculate.
Where a product has multi speeds, a typical installation has been used for the below calculations. *Running cost does not include the use of the heater on the heater model


pence
(Your current electricity cost in pence per hour. This will be listed on your electric bill)
hours
(The average number of hours per day fan to run in Trickle mode)
hours
(The average number of hours per day fan to run in Boost mode)

Based on the inputted figures, estimated running costs would be:

Overview

The Long Case Axial range of fans incorporates manually adjustable pitch impellers which provide a comprehensive range of duties offering high performance and pressure characteristics.

Available in twelve sizes ranging from 315 to 1250mm diameter and performances from 0.24m3/s to 38m3/s (864m3/h to 136,800m3/h) with pressure development up to 1250Pa. The casing is constructed from rolled steel plate complete with flanges and protected with a tough, galvanised finish.

The Long Case Axial range has a range of accessories available which include: Axial Ancillary Pack, Cased Axial Attenuator, Mounting Feet, Wire Inlet Guard, Coupling Flange & Speed Controllers.

Motor / Impellers

The motors are specially selected for optimum performance and efficiency. Ball bearings are greased for life and allow the fan to be installed at any angle. Suitable for continuous operation in relative humidity up to 95%. Motors are protected to IP55 against dust and water jets complying with BS EN 60529. They have ribbed aluminium body castings for efficient cooling. Motor insulation is Class 'F' (from -35°C to +54°C). Star/delta starting is recommended for motor output above 4kW.

Impeller blades are clamped in a split cast aluminium hub, with a keywayed mild steel insert enabling positive locking of the impeller assembly to the motor shaft, this also allows manual adjustment of the pitch angle giving a wide selection of performance details.

Terminal Box
To IP55, protected against dust and water jets from any angle, allowing outside applications.

Electrical

Single phase 220-240V 50 Hz capacitor start and run. Three phase 380-415V 50Hz. Protection of the motor must be provided by an overload current sensing device (eg. D.O.L Starter or Star/Delta starter where appropriate) or the guarantee will be invalidated. All models are available with 4 pole motors for 315 up to 1250mm with additional 2 pole motors available from 315 up to 630mm.

Motors protected to IP55 against dust & water jets.
Composite cast aluminium axial impellers
Terminal box protected to IP55

Selection Guide

All stocked fans have the impellers set at the maximum pitch angle relative to the motor power of the fan unit and are available for adjustment below the pre-set pitch angle (adjustment down in 2° intervals). These units will be factory set before despatch.

Technical

DIMENSIONS:

No. A B C D E F G
LC31 A2/1&3/ 8-32 315 420 355 385 8 10 224
LC31 A4/1&3/ 8-32 315 420 355 385 8 10 224
LC35 A2/1&3/ 8-32 355 420 395 425 8 10 250
LC35 A4/1&3/ 8-32 355 420 395 425 8 10 250
LC40 A2/1&3/ 8-28 400 435 450 480 8 12 280
LC40 A2/1&3/ 8-32 400 435 450 480 8 12 280
LC45 A2/3/ 8-24 450 435 500 530 8 12 315
LC45 A4/1&3/ 8-32 450 435 500 530 8 12 315
LC50 A2/3/ 8-16 500 470 560 590 12 12 315
LC50 A2/3/ 8-26 500 565 560 590 12 12 315
LC50 A4/1&3/ 8-28 500 470 560 590 12 12 315
LC56 A2/3/ 8-18 560 470 620 650 12 12 355
LC56 A2/3/ 20-24 560 565 620 650 12 12 355
LC56 A4/1&3/ 8-26 560 470 620 650 12 12 355
LC63 A2/3/ 8-16 630 565 690 720 12 12 400
LC63 A4/1/ 8-22 630 470 690 720 12 12 400
LC63 A4/3/ 8-30 630 470 690 720 12 12 400
LC71 A4/3/ 8-30 710 470 770 800 16 12 410
LC80 A4/3/ 8-18 800 470 860 890 16 12 450
LC80 A4/3/ 20-28 800 565 860 890 16 12 450
LC90 A4/3/ 8-18 900 565 970 1038 16 14 500
LC90 A4/3/ 20-32 900 700 970 1038 16 14 500
LC100 A4/3/ 8-12 1000 565 1070 1138 16 14 555
LC100 A4/3/ 14-22 1000 700 1070 1138 16 14 555
LC100 A4/3/ 24-28 1000 790 1070 1138 16 14 555
LC125 A4/3/ 8-14 1250 950 1320 1390 20 15 868
LC125 A4/3/ 16-24 1250 1100 1320 1390 20 15 868

Downloads