Lo-Carbon Sentinel Multivent / Plus
Please click here for the latest product alternative
• Reduces your carbon footprint
• Recognised in SAP PCDB
• Specific fan power as low as 0.16 W/l/s
• Suitable for use with external sensors and controllers
• Wireless control option
• Complies with Building Regulations ADF and ADL
• Manufactured in the UK from recyclable materials
Sentinel Multivent continuous mechanical extract ventilation, MEV is designed for the simultaneous ventilation of separate areas in the home or as a multipoint extraction system for a wide range of commercial applications. The units can be installed at any angle. Where the ambient air has a high humidity content condensate drains are provided.
In support of Sentinel Multivent, Vent-Axia offers:
• Practical advice on product selection and installation
• Guidance on solutions to meet legislation requirements
• Project management and site deliveries
• After sales support and maintenance information
The need to improve efficiency
Sentinel Multivent has been designed to meet the exacting demands of developers, installers and users offering advanced control options and easier installation and commissioning.
• Demand Control - enables precise ventilation rate, is set in 1% increments based on property size
• Integral LCD display allows the installer to select appropriate low, normal and boost speeds to meet demand
• Manual and automatic control options
• Integral adjustable overrun timer and delay on timer
• Plug-n-Play automatic sensor detection
• Switched live and SELV connections
• Dry Out setting – Option set at installation, Sentinel Multivent will run on boost for 1 week to assist in removing moisture
• Optional Wireless Control – up to 4 controllers on any one system
• Energy efficient EC/DC motors - 1/3 less energy lost to heat than a conventional AC motor
• Low Specific Fan Power (SFP) making it one of the most efficient products on the market
Legislation
• Meets Building Regulations Approved Document F (System 3)
• Recognised in SAP PCDB up to kitchen + 6 wet rooms
• Meets carbon footprint reduction targets
• Lowest SFP figures of any demand control MEV system
The need for better health
Removal of pollutants such as moisture, carbon dioxide and external fumes are all important factors in maintaining indoor air quality, helping to create a healthier living environment.
• The integral humidity sensor (Sentinel Multivent H) increases fan speed in proportion to relative humidity levels, saving energy and reducing noise
• The sensor also reacts to small but rapid increases in humidity, even if the normal trigger threshold is not reached. This unique feature ensures adequate ventilation, even for the smallest wet room
• Night time relative humidity increment setback feature suppresses nuisance tripping as humidity gradually increases with falling temperature
SAP PCDB
In order to make the right choice, developers and contractors should refer to Building Regulations ADL1a, SAP 2012 and SAP PCDB. SAP PCDB was launched in June 2006 to reward innovative ventilation manufacturers by testing and listing energy efficient products that assist in helping developers meet their Target Emission Rates (TER). SAP is the underpinning methodology behind the Energy Performance Certificates and is used to demonstrate compliance with Building Regulations for Dwellings - Approved Document L (England and Wales), Section 6 (Scotland) and Approved Document F (Northern Ireland). SAP PCDB specifically relates to wholehouse ventilation systems and lists a number of Vent-Axia Mechanical Ventilation solutions which offer an improved SAP rating over and above the default for these product types.
Your Carbon Footprint
The Carbon Footprint is a measure of the amount of carbon dioxide (CO2) emitted through the burning of fossil fuels. From a residential and commercial building perspective, it is the amount of carbon generated when you consume a kilowatt of electricity. Reducing a building’s carbon footprint will ultimately reduce electricity bills and save money for every individual household or business. It will also help meet the UK target for the reduction of emissions, as well as allowing you to help the environment.
DIMENSIONS:
Dimensions (mm)
A | B | C | D | E | F | G | H | I | J |
340 | 72.5 | 25 | 15 | 360 | 214 | 310 | 260 | 150 | 85 |
Continuous running mechanical extract system, designed for the simultaneous ventilation of separate areas in the home or as a multipoint extraction system for a wide range of commercial applications.
Continuous running mechanical extract system with integral humidity sensor, designed for the simultaneous ventilation of separate areas in the home or as a multipoint extraction system for a wide range of commercial applications. The integral humidity sensor increases fan speed in proportion to relative humidity levels, saving energy and reducing noise.
Designed specifically for the Lo-Carbon product range. This self programming electronic On/Off wall mounted humidity sensor reacts to any rapid increase in humidity and temperature by switching a VentAxia fan ‘On’ for rapid removal of moisture laden air in domestic bathrooms and kitchens. Night time relative humidity increment setback feature suppresses nuisance tripping when the humidity level gradually rises as the temperature falls.
- Pullcord override and neon indicator.
- Changeover relay switch.
- Operating range: 30%-90%RH.
- Ambient operating temperature +5°C to +40°C.
- Dimensions: 87 x 87 x 33mm (H x W x D).
- Will fit single gang box for surface mounting.
Automatically reacts to the deterioration of air quality, sensing tobacco smoke, smells and toilet odours to regulate mechanically ventilated areas, such as cinemas, pubs, clubs, restaurants, kitchens, toilets and conference rooms. The sensor switches when the air quality declines below an adjustable preset level. This is registered by a self-cleaning ceramic sensing head. The air quality sensor should not be used for the detection of combustible gases. Ambient operating temperature range 0°C to +50°C. MIN - MAX mode or direct Damper control. Dimensions:87 x 157 x 47mm (H xWxD) Surface mounted. 1 - 25 min O/R timer. Supply voltage 24V DC SELV.
Humidity Control is automatic and can be set to switch between 65 and 90%RH. An integral pullcord provides a manual override function if required. Can be wired for either ON/OFF or Trickle Boost operation. Set Point adjustable. Maximum switching load 1 amp inductive. Pullcord override indicator Ambient operating temperature 0°C to +40°C. Dimensions:87 x 87 x 33mm (H x W x D). Supply voltage 24V DC SELV. Humidity sensors should be sited approx. 100mm below ceiling level and not above cupboards, refer to siting details in fitting and wiring instructions supplied with product.
A wall or ceiling mounted movement detector for use with any domestic Vent-Axia mains voltage product. Also suitable for use with Vent-Axia T-Series controllers on ‘Auto’ setting and ITC controllers on sensor mode. Visionex PIR can be wired for either On/Off or Trickle/ Boost operation.
- Fits any UK single gang mounting box.
- Adjustable timer overrun (5-25 minutes).
- Range of detection up to 10 metres.
- Designed to meet IP43.
- Ambient operating temperature range 0°C to +50°C.
- Maximum load: 2.5 amps/600W inductive. Not suitable for use with lighting.
- Internal use only.
- No switched live required for internal rooms and WCs.
- Double insulated.
- Volt-free contacts.
- Supply voltage 220-240V/1/50Hz.
The integral humidity sensor increases speed in proportion to relative humidity levels, saving energy and reducing noise. The sensor also reacts to small but rapid increases in humidity, even if the normal trigger threshold is not reached. This unique feature ensures adequate ventilation, even for the smallest wet-room. • Simple Plug-n-Play installation • Eliminates the need for additional controllers or sensors • Reacts to any rapid increases in relative humidity or relative humidity above 60% • Future proof – can be fitted after installation • Proportional Control • Self programming
• Manual boost
• Adjustable overrun timer
• Easy wire-less installation
• Reduces installation time
• Future proof - add more controllers at any time
IMPORTANT – This wireless controller is not compatible with any new Sentinel Multivent Ranges (white units). It is only compatible with these Sentinel Multivent part numbers; 445655, 445655A & 407849.
HVAC temperature and carbon dioxide room sensor for ventilation control of residential areas, office areas and classrooms. Used with Sentinel in Proportional control mode. Sensor will monitor both CO2 and temperature levels between the set points, the Sentinel air extraction rate will follow the higher of the 2 outputs. 24V DC SELV. 0 - 2000ppm CO2 working range. 0 - 50°C Temperature working range. Auto-calibrating NDIR CO2 absorption sensor. Thin film platinum temperature sensor for high accuracy. Dimensions:100 x 84 x 25mm (H x W x D).
Raadpleeg de tab Downloads voor technische informatie
ESTIMATED RUNNING COSTS
Calculate estimated running costs for this product using the tool below.
For average costs*, leave the default values in place or enter your own figures in the boxes to recalculate.
Where a product has multi speeds, a typical installation has been used for the below calculations. *Running cost does not include the use of the heater on the heater model
Based on the inputted figures, estimated running costs would be:
Overview
Sentinel Multivent continuous mechanical extract ventilation, MEV is designed for the simultaneous ventilation of separate areas in the home or as a multipoint extraction system for a wide range of commercial applications. The units can be installed at any angle. Where the ambient air has a high humidity content condensate drains are provided.
In support of Sentinel Multivent, Vent-Axia offers:
• Practical advice on product selection and installation
• Guidance on solutions to meet legislation requirements
• Project management and site deliveries
• After sales support and maintenance information
The need to improve efficiency
Sentinel Multivent has been designed to meet the exacting demands of developers, installers and users offering advanced control options and easier installation and commissioning.
• Demand Control - enables precise ventilation rate, is set in 1% increments based on property size
• Integral LCD display allows the installer to select appropriate low, normal and boost speeds to meet demand
• Manual and automatic control options
• Integral adjustable overrun timer and delay on timer
• Plug-n-Play automatic sensor detection
• Switched live and SELV connections
• Dry Out setting – Option set at installation, Sentinel Multivent will run on boost for 1 week to assist in removing moisture
• Optional Wireless Control – up to 4 controllers on any one system
• Energy efficient EC/DC motors - 1/3 less energy lost to heat than a conventional AC motor
• Low Specific Fan Power (SFP) making it one of the most efficient products on the market
Legislation
• Meets Building Regulations Approved Document F (System 3)
• Recognised in SAP PCDB up to kitchen + 6 wet rooms
• Meets carbon footprint reduction targets
• Lowest SFP figures of any demand control MEV system
The need for better health
Removal of pollutants such as moisture, carbon dioxide and external fumes are all important factors in maintaining indoor air quality, helping to create a healthier living environment.
• The integral humidity sensor (Sentinel Multivent H) increases fan speed in proportion to relative humidity levels, saving energy and reducing noise
• The sensor also reacts to small but rapid increases in humidity, even if the normal trigger threshold is not reached. This unique feature ensures adequate ventilation, even for the smallest wet room
• Night time relative humidity increment setback feature suppresses nuisance tripping as humidity gradually increases with falling temperature
SAP PCDB
In order to make the right choice, developers and contractors should refer to Building Regulations ADL1a, SAP 2012 and SAP PCDB. SAP PCDB was launched in June 2006 to reward innovative ventilation manufacturers by testing and listing energy efficient products that assist in helping developers meet their Target Emission Rates (TER). SAP is the underpinning methodology behind the Energy Performance Certificates and is used to demonstrate compliance with Building Regulations for Dwellings - Approved Document L (England and Wales), Section 6 (Scotland) and Approved Document F (Northern Ireland). SAP PCDB specifically relates to wholehouse ventilation systems and lists a number of Vent-Axia Mechanical Ventilation solutions which offer an improved SAP rating over and above the default for these product types.
Your Carbon Footprint
The Carbon Footprint is a measure of the amount of carbon dioxide (CO2) emitted through the burning of fossil fuels. From a residential and commercial building perspective, it is the amount of carbon generated when you consume a kilowatt of electricity. Reducing a building’s carbon footprint will ultimately reduce electricity bills and save money for every individual household or business. It will also help meet the UK target for the reduction of emissions, as well as allowing you to help the environment.
Technical
DIMENSIONS:
Dimensions (mm)
A | B | C | D | E | F | G | H | I | J |
340 | 72.5 | 25 | 15 | 360 | 214 | 310 | 260 | 150 | 85 |
Models
Continuous running mechanical extract system, designed for the simultaneous ventilation of separate areas in the home or as a multipoint extraction system for a wide range of commercial applications.
Continuous running mechanical extract system with integral humidity sensor, designed for the simultaneous ventilation of separate areas in the home or as a multipoint extraction system for a wide range of commercial applications. The integral humidity sensor increases fan speed in proportion to relative humidity levels, saving energy and reducing noise.
Accessories
Designed specifically for the Lo-Carbon product range. This self programming electronic On/Off wall mounted humidity sensor reacts to any rapid increase in humidity and temperature by switching a VentAxia fan ‘On’ for rapid removal of moisture laden air in domestic bathrooms and kitchens. Night time relative humidity increment setback feature suppresses nuisance tripping when the humidity level gradually rises as the temperature falls.
- Pullcord override and neon indicator.
- Changeover relay switch.
- Operating range: 30%-90%RH.
- Ambient operating temperature +5°C to +40°C.
- Dimensions: 87 x 87 x 33mm (H x W x D).
- Will fit single gang box for surface mounting.
Automatically reacts to the deterioration of air quality, sensing tobacco smoke, smells and toilet odours to regulate mechanically ventilated areas, such as cinemas, pubs, clubs, restaurants, kitchens, toilets and conference rooms. The sensor switches when the air quality declines below an adjustable preset level. This is registered by a self-cleaning ceramic sensing head. The air quality sensor should not be used for the detection of combustible gases. Ambient operating temperature range 0°C to +50°C. MIN - MAX mode or direct Damper control. Dimensions:87 x 157 x 47mm (H xWxD) Surface mounted. 1 - 25 min O/R timer. Supply voltage 24V DC SELV.
Humidity Control is automatic and can be set to switch between 65 and 90%RH. An integral pullcord provides a manual override function if required. Can be wired for either ON/OFF or Trickle Boost operation. Set Point adjustable. Maximum switching load 1 amp inductive. Pullcord override indicator Ambient operating temperature 0°C to +40°C. Dimensions:87 x 87 x 33mm (H x W x D). Supply voltage 24V DC SELV. Humidity sensors should be sited approx. 100mm below ceiling level and not above cupboards, refer to siting details in fitting and wiring instructions supplied with product.
A wall or ceiling mounted movement detector for use with any domestic Vent-Axia mains voltage product. Also suitable for use with Vent-Axia T-Series controllers on ‘Auto’ setting and ITC controllers on sensor mode. Visionex PIR can be wired for either On/Off or Trickle/ Boost operation.
- Fits any UK single gang mounting box.
- Adjustable timer overrun (5-25 minutes).
- Range of detection up to 10 metres.
- Designed to meet IP43.
- Ambient operating temperature range 0°C to +50°C.
- Maximum load: 2.5 amps/600W inductive. Not suitable for use with lighting.
- Internal use only.
- No switched live required for internal rooms and WCs.
- Double insulated.
- Volt-free contacts.
- Supply voltage 220-240V/1/50Hz.
The integral humidity sensor increases speed in proportion to relative humidity levels, saving energy and reducing noise. The sensor also reacts to small but rapid increases in humidity, even if the normal trigger threshold is not reached. This unique feature ensures adequate ventilation, even for the smallest wet-room. • Simple Plug-n-Play installation • Eliminates the need for additional controllers or sensors • Reacts to any rapid increases in relative humidity or relative humidity above 60% • Future proof – can be fitted after installation • Proportional Control • Self programming
• Manual boost
• Adjustable overrun timer
• Easy wire-less installation
• Reduces installation time
• Future proof - add more controllers at any time
IMPORTANT – This wireless controller is not compatible with any new Sentinel Multivent Ranges (white units). It is only compatible with these Sentinel Multivent part numbers; 445655, 445655A & 407849.
HVAC temperature and carbon dioxide room sensor for ventilation control of residential areas, office areas and classrooms. Used with Sentinel in Proportional control mode. Sensor will monitor both CO2 and temperature levels between the set points, the Sentinel air extraction rate will follow the higher of the 2 outputs. 24V DC SELV. 0 - 2000ppm CO2 working range. 0 - 50°C Temperature working range. Auto-calibrating NDIR CO2 absorption sensor. Thin film platinum temperature sensor for high accuracy. Dimensions:100 x 84 x 25mm (H x W x D).