Lo-Carbon T-Series Roof Fan
• Reduces your carbon footprint
• Extract / intake model in 2 sizes: 9” and 12”
• Long life Lo-Carbon motor lasts twice as long as other conventional motors
• Up to 70% energy saving
• Easy fit connector Top Socket, standard on all models.
Select a product
UK’s No. 1 Commercial Fan
The Lo-Carbon T-Series Fan range utilises a low energy DC motor, developed to improve performance, lower running costs and maintain T-Series’ rugged reliability.
Roof Fitting Kit
Designing ventilation systems with the unit mounted in a skylight or a flat roof is easy. With a low profile cowl, the Lo-Carbon T-Series Roof model is suitable for installation in horizontal, angled (max pitch 30deg) and vertical glass and for fixing plates in roofs. For vertical windows or walls in exposed areas and single and double glazing including most types of glass up to 32mm thick. Greater thicknesses can be accommodated using extended fixing rod sets. Both sizes of Vent-Axia roof plate assemblies can be fitted easily into flat roofs.
Instantaneous Shutter
With energy saving in mind, Lo-Carbon T-Series models are supplied complete with an integral, instantaneous, automatic louvre shutter concealed behind the interior grille.
It will operate on both intake and extract and at any angle of mounting. The shutter is electronically controlled by an actuator with a damped action giving quiet operation during instant opening and closing.
When the fan is used with a Lo-Carbon T-Series controller, the shutter can be set open with the fan motor switched off to provide natural ventilation without the security risk of an open window.
Top Socket
A connector Top Socket is standard on all T-Series fans. Allowing fast and trouble-free mains connection.
Electrical
Motor purpose-designed. Suitable for running at any angle. Quiet running, enclosed. Suitable for operation in ambient temperatures from -40°C to +50°C.
Fitted with self resetting Standard Thermal Overload Protection (S.T.O.P.).
Supply voltage 220-240V/1/50Hz
Click here for technical information, within our Online Product Selector. After, select your required fan model from the list to display Performance, Sound, Dimensions and Electrical Data.
PERFORMANCE:
Unit Size | LoWatt TX9RF Wireless | LoWatt TX9RF | |
Stock Ref. No. | 45 61 72 | 45 61 68 | |
Amps @ 240V | 0.34 | 0.34 | |
Extract Performance m³/h | Low | 313 | 313 |
Extract Performance m³/h | Med | 526 | 526 |
Extract Performance m³/h | High | 693 | 693 |
Watts (high) | 29 | 29 | |
dB(A) (med) @ 3m | 40 | 40 | |
--- | |||
Unit Size | LoWatt TX12RF Wireless | LoWatt TX12RF | |
Stock Ref. No. | 45 61 80 | 45 61 76 | |
Amps @ 240V | 0.69 | 0.69 | |
Extract Performance m³/h | Low | 518 | 518 |
Extract Performance m³/h | Med | 1017 | 1017 |
Extract Performance m³/h | High | 1194 | 1194 |
Watts (high) | 67 | 67 | |
dB(A) (med) @ 3m | 48 | 48 | |
--- | |||
Recommended controller: | |||
Wired Stock Ref. No. 45 58 73 | |||
DIMENSIONS:
Size | A | B | C | D | E | F | Fixing Hole | Weight kg |
230mm | 136 | 150 | 304 | 302 | 54 | 400 | 260 | 6.22 |
300mm | 171 | 177 | 381 | 378 | 54 | 500 | 337 | 9.28 |
Designing ventilation systems with the fan mounted in a skylight or a flat roof is easy. With a low profile cowl, the Lo-Carbon T-Series Roof model is suitable for installation in horizontal, angled and vertical glass and for fixing plates in roofs. For vertical windows or walls in exposed areas and single and double glazing including most types of glass up to 32mm thick. Greater thicknesses can be accommodated using extended fixing rod sets. Both sizes of Vent-Axia roof plate assemblies can be fitted easily into flat roofs.
Designing ventilation systems with the fan mounted in a skylight or a flat roof is easy. With a low profile cowl, the Lo-Carbon T-Series Roof model is suitable for installation in horizontal, angled and vertical glass and for fixing plates in roofs. For vertical windows or walls in exposed areas and single and double glazing including most types of glass up to 32mm thick. Greater thicknesses can be accommodated using extended fixing rod sets. Both sizes of Vent-Axia roof plate assemblies can be fitted easily into flat roofs.
Lo-Carbon T-Series Controllers are available in both Wired and Wire-less FM versions. The three speed push button surface mounted controllers provide intake/extract and shutter only options and auto mode position for use with external sensors. Wired versions are connected to the fan using a plug-in Safety Extra Low Voltage 2-core signal cable supplied (10m), allowing simple and safe installation. Alternatively, the Wire-less FM controller offers full control without the need for any wiring, ideal for premises where installations need to be carried out with minimum disruption or where surface wiring can be classed as unsightly or obtrusive.
Every LoWatt T-Series Wire-less FM Controller uses unique digital signals to ensure trouble free operation. The controller will transmit through walls and floors allowing complete flexibility of design to control fans up to 30m away. Wire-less FM Controllers can dramatically reduce installation time and costs. The Immediate benefit being the elimination of unsightly wiring. Wire-less FM Controllers can be easily installed in an variety of applications including assembly rooms, banks, hospitals, laboratories, restaurants, schools, shops and public houses.
240VAC 50Hz.
European Patent No: 2298057
An adjustable set point, solid state On/Off sensor. A pullcord provides manual override, indicated by lamp. Adjustable from 65 to 90% relative humidity. Can be wired into controller ‘Auto’ mode connections. Incorporates changeover switch to select low/high speed.
- Setting range 65% - 90%RH.
- Maximum switching load 1 Amp inductive.
- Pullcord override indicated by lamp.
- Ambient operating temperature 0°C to +40°C.
- Dimensions: 87 x 87 x 33mm. (H x W x D).
- Supply voltage 220-240V/1/50Hz.
A wall or ceiling mounted movement detector for use with any domestic Vent-Axia mains voltage product. Also suitable for use with Vent-Axia T-Series controllers on ‘Auto’ setting and ITC controllers on sensor mode. Visionex PIR can be wired for either On/Off or Trickle/ Boost operation.
- Fits any UK single gang mounting box.
- Adjustable timer overrun (5-25 minutes).
- Range of detection up to 10 metres.
- Designed to meet IP43.
- Ambient operating temperature range 0°C to +50°C.
- Maximum load: 2.5 amps/600W inductive. Not suitable for use with lighting.
- Internal use only.
- No switched live required for internal rooms and WCs.
- Double insulated.
- Volt-free contacts.
- Supply voltage 220-240V/1/50Hz.
Raadpleeg de tab Downloads voor technische informatie
ESTIMATED RUNNING COSTS
Calculate estimated running costs for this product using the tool below.
For average costs*, leave the default values in place or enter your own figures in the boxes to recalculate.
Where a product has multi speeds, a typical installation has been used for the below calculations. *Running cost does not include the use of the heater on the heater model
Based on the inputted figures, estimated running costs would be:
Overview
UK’s No. 1 Commercial Fan
The Lo-Carbon T-Series Fan range utilises a low energy DC motor, developed to improve performance, lower running costs and maintain T-Series’ rugged reliability.
Roof Fitting Kit
Designing ventilation systems with the unit mounted in a skylight or a flat roof is easy. With a low profile cowl, the Lo-Carbon T-Series Roof model is suitable for installation in horizontal, angled (max pitch 30deg) and vertical glass and for fixing plates in roofs. For vertical windows or walls in exposed areas and single and double glazing including most types of glass up to 32mm thick. Greater thicknesses can be accommodated using extended fixing rod sets. Both sizes of Vent-Axia roof plate assemblies can be fitted easily into flat roofs.
Instantaneous Shutter
With energy saving in mind, Lo-Carbon T-Series models are supplied complete with an integral, instantaneous, automatic louvre shutter concealed behind the interior grille.
It will operate on both intake and extract and at any angle of mounting. The shutter is electronically controlled by an actuator with a damped action giving quiet operation during instant opening and closing.
When the fan is used with a Lo-Carbon T-Series controller, the shutter can be set open with the fan motor switched off to provide natural ventilation without the security risk of an open window.
Top Socket
A connector Top Socket is standard on all T-Series fans. Allowing fast and trouble-free mains connection.
Electrical
Motor purpose-designed. Suitable for running at any angle. Quiet running, enclosed. Suitable for operation in ambient temperatures from -40°C to +50°C.
Fitted with self resetting Standard Thermal Overload Protection (S.T.O.P.).
Supply voltage 220-240V/1/50Hz
Technical
Click here for technical information, within our Online Product Selector. After, select your required fan model from the list to display Performance, Sound, Dimensions and Electrical Data.
PERFORMANCE:
Unit Size | LoWatt TX9RF Wireless | LoWatt TX9RF | |
Stock Ref. No. | 45 61 72 | 45 61 68 | |
Amps @ 240V | 0.34 | 0.34 | |
Extract Performance m³/h | Low | 313 | 313 |
Extract Performance m³/h | Med | 526 | 526 |
Extract Performance m³/h | High | 693 | 693 |
Watts (high) | 29 | 29 | |
dB(A) (med) @ 3m | 40 | 40 | |
--- | |||
Unit Size | LoWatt TX12RF Wireless | LoWatt TX12RF | |
Stock Ref. No. | 45 61 80 | 45 61 76 | |
Amps @ 240V | 0.69 | 0.69 | |
Extract Performance m³/h | Low | 518 | 518 |
Extract Performance m³/h | Med | 1017 | 1017 |
Extract Performance m³/h | High | 1194 | 1194 |
Watts (high) | 67 | 67 | |
dB(A) (med) @ 3m | 48 | 48 | |
--- | |||
Recommended controller: | |||
Wired Stock Ref. No. 45 58 73 | |||
DIMENSIONS:
Size | A | B | C | D | E | F | Fixing Hole | Weight kg |
230mm | 136 | 150 | 304 | 302 | 54 | 400 | 260 | 6.22 |
300mm | 171 | 177 | 381 | 378 | 54 | 500 | 337 | 9.28 |
Models
Designing ventilation systems with the fan mounted in a skylight or a flat roof is easy. With a low profile cowl, the Lo-Carbon T-Series Roof model is suitable for installation in horizontal, angled and vertical glass and for fixing plates in roofs. For vertical windows or walls in exposed areas and single and double glazing including most types of glass up to 32mm thick. Greater thicknesses can be accommodated using extended fixing rod sets. Both sizes of Vent-Axia roof plate assemblies can be fitted easily into flat roofs.
Designing ventilation systems with the fan mounted in a skylight or a flat roof is easy. With a low profile cowl, the Lo-Carbon T-Series Roof model is suitable for installation in horizontal, angled and vertical glass and for fixing plates in roofs. For vertical windows or walls in exposed areas and single and double glazing including most types of glass up to 32mm thick. Greater thicknesses can be accommodated using extended fixing rod sets. Both sizes of Vent-Axia roof plate assemblies can be fitted easily into flat roofs.
Accessories
Lo-Carbon T-Series Controllers are available in both Wired and Wire-less FM versions. The three speed push button surface mounted controllers provide intake/extract and shutter only options and auto mode position for use with external sensors. Wired versions are connected to the fan using a plug-in Safety Extra Low Voltage 2-core signal cable supplied (10m), allowing simple and safe installation. Alternatively, the Wire-less FM controller offers full control without the need for any wiring, ideal for premises where installations need to be carried out with minimum disruption or where surface wiring can be classed as unsightly or obtrusive.
Every LoWatt T-Series Wire-less FM Controller uses unique digital signals to ensure trouble free operation. The controller will transmit through walls and floors allowing complete flexibility of design to control fans up to 30m away. Wire-less FM Controllers can dramatically reduce installation time and costs. The Immediate benefit being the elimination of unsightly wiring. Wire-less FM Controllers can be easily installed in an variety of applications including assembly rooms, banks, hospitals, laboratories, restaurants, schools, shops and public houses.
240VAC 50Hz.
European Patent No: 2298057
An adjustable set point, solid state On/Off sensor. A pullcord provides manual override, indicated by lamp. Adjustable from 65 to 90% relative humidity. Can be wired into controller ‘Auto’ mode connections. Incorporates changeover switch to select low/high speed.
- Setting range 65% - 90%RH.
- Maximum switching load 1 Amp inductive.
- Pullcord override indicated by lamp.
- Ambient operating temperature 0°C to +40°C.
- Dimensions: 87 x 87 x 33mm. (H x W x D).
- Supply voltage 220-240V/1/50Hz.
A wall or ceiling mounted movement detector for use with any domestic Vent-Axia mains voltage product. Also suitable for use with Vent-Axia T-Series controllers on ‘Auto’ setting and ITC controllers on sensor mode. Visionex PIR can be wired for either On/Off or Trickle/ Boost operation.
- Fits any UK single gang mounting box.
- Adjustable timer overrun (5-25 minutes).
- Range of detection up to 10 metres.
- Designed to meet IP43.
- Ambient operating temperature range 0°C to +50°C.
- Maximum load: 2.5 amps/600W inductive. Not suitable for use with lighting.
- Internal use only.
- No switched live required for internal rooms and WCs.
- Double insulated.
- Volt-free contacts.
- Supply voltage 220-240V/1/50Hz.