Traditional T-Series- Darkroom Fan
- Extract/intake models in 4 sizes: 6”, 7”, 9” and 12”
- Specially designed to provide extract/intake ventilation in darkrooms, X-ray areas, etc
- Patented electronic shutter system ensures quiet, trouble free operation
- For the very best from your fan use the Ecotronic controller
- Integrated component design allows all parts to be dismantled for cleaning without the use of specialist tools
- Easy fit connector Top Socket, standard on all models
Select a product
UK’s No. 1 Commercial Fan
A range designed for photographic, medical, dental and veterinarian applications - used also for opticians and other specialist applications. Most darkrooms need a minimum of ten air changes per hour for comfort and efficiency. For rooms containing heat producing equipment (eg: print glazers) a higher rate of air change may be desirable. The Darkroom fitting kit has two cowls, the interior cowl being designed to give light protection. It can be installed in windows, partitions, external walls or roofs. Extended fixing rods for fixing thicknesses up to 370mm are supplied with the unit. Provision should be made for adequate air replacement through Vent-Axia non-vision grilles.
Shutter
With energy savings in mind Darkroom models are supplied complete with an integral instantaneous automatic louvre shutter concealed behind the interior cowl. Operates on intake and extract at any angle of mounting.
When used with a T-Series or Ecotronic controller, the shutter can be set open with the fan motor switched Off to provide natural ventilation without the security risk of an open window.
Top Socket
A connector Top Socket is standard on all T-Series fans. Allowing fast and trouble-free mains connection.
Electrical
Suitable for running at any angle. Quiet running, enclosed. Fitted with Standard Thermal Overload Protection (S.T.O.P.).
Supply voltage: 220-240V/1/50Hz.
Suitable for operation in ambient temperatures from -40°C to +50°C.
Click here for technical information, within our Online Product Selector. After, select your required fan model from the list to display Performance, Sound, Dimensions and Electrical Data.
DIMENSIONS:
Size | 6 (150mm) | 7 (190mm) | 9 (230mm) | 12 (300mm) |
A | 100 | 136 | 136 | 171 |
B | 196 | 206 | 229 | 308 |
C | 285 | 400 | 400 | 500 |
D | 220 | 258 | 302 | 378 |
E | 226 | 265 | 304 | 381 |
F | 19 | 19 | 19 | 19 |
Fixing Hole Diameter | 184 | 222 | 260 | 337 |
Weight (kg) | 4.13 | 5.33 | 6.60 | 10.05 |
For groups of units of any one size up to a total of 400 watts. Do not mix T-Series with Standard Range ventilating units on one controller.
Designed specifically for the Lo-Carbon product range. This self programming electronic On/Off wall mounted humidity sensor reacts to any rapid increase in humidity and temperature by switching a VentAxia fan ‘On’ for rapid removal of moisture laden air in domestic bathrooms and kitchens. Night time relative humidity increment setback feature suppresses nuisance tripping when the humidity level gradually rises as the temperature falls.
- Pullcord override and neon indicator.
- Changeover relay switch.
- Operating range: 30%-90%RH.
- Ambient operating temperature +5°C to +40°C.
- Dimensions: 87 x 87 x 33mm (H x W x D).
- Will fit single gang box for surface mounting.
Automatically reacts to the deterioration of air quality, sensing tobacco smoke, smells and toilet odours to regulate mechanically ventilated areas, such as cinemas, pubs, clubs, restaurants, kitchens, toilets and conference rooms. The sensor switches when the air quality declines below an adjustable preset level. This is registered by a self-cleaning ceramic sensing head. The air quality sensor should not be used for the detection of combustible gases. Ambient operating temperature range 0°C to +50°C. MIN - MAX mode or direct Damper control. Dimensions:87 x 157 x 47mm (H xWxD) Surface mounted. 1 - 25 min O/R timer. Supply voltage 24V DC SELV.
Humidity Control is automatic and can be set to switch between 65 and 90%RH. An integral pullcord provides a manual override function if required. Can be wired for either ON/OFF or Trickle Boost operation. Set Point adjustable. Maximum switching load 1 amp inductive. Pullcord override indicator Ambient operating temperature 0°C to +40°C. Dimensions:87 x 87 x 33mm (H x W x D). Supply voltage 24V DC SELV. Humidity sensors should be sited approx. 100mm below ceiling level and not above cupboards, refer to siting details in fitting and wiring instructions supplied with product.
Raadpleeg de tab Downloads voor technische informatie
ESTIMATED RUNNING COSTS
Calculate estimated running costs for this product using the tool below.
For average costs*, leave the default values in place or enter your own figures in the boxes to recalculate.
Where a product has multi speeds, a typical installation has been used for the below calculations. *Running cost does not include the use of the heater on the heater model
Based on the inputted figures, estimated running costs would be:
Overview
UK’s No. 1 Commercial Fan
A range designed for photographic, medical, dental and veterinarian applications - used also for opticians and other specialist applications. Most darkrooms need a minimum of ten air changes per hour for comfort and efficiency. For rooms containing heat producing equipment (eg: print glazers) a higher rate of air change may be desirable. The Darkroom fitting kit has two cowls, the interior cowl being designed to give light protection. It can be installed in windows, partitions, external walls or roofs. Extended fixing rods for fixing thicknesses up to 370mm are supplied with the unit. Provision should be made for adequate air replacement through Vent-Axia non-vision grilles.
Shutter
With energy savings in mind Darkroom models are supplied complete with an integral instantaneous automatic louvre shutter concealed behind the interior cowl. Operates on intake and extract at any angle of mounting.
When used with a T-Series or Ecotronic controller, the shutter can be set open with the fan motor switched Off to provide natural ventilation without the security risk of an open window.
Top Socket
A connector Top Socket is standard on all T-Series fans. Allowing fast and trouble-free mains connection.
Electrical
Suitable for running at any angle. Quiet running, enclosed. Fitted with Standard Thermal Overload Protection (S.T.O.P.).
Supply voltage: 220-240V/1/50Hz.
Suitable for operation in ambient temperatures from -40°C to +50°C.
Technical
Click here for technical information, within our Online Product Selector. After, select your required fan model from the list to display Performance, Sound, Dimensions and Electrical Data.
DIMENSIONS:
Size | 6 (150mm) | 7 (190mm) | 9 (230mm) | 12 (300mm) |
A | 100 | 136 | 136 | 171 |
B | 196 | 206 | 229 | 308 |
C | 285 | 400 | 400 | 500 |
D | 220 | 258 | 302 | 378 |
E | 226 | 265 | 304 | 381 |
F | 19 | 19 | 19 | 19 |
Fixing Hole Diameter | 184 | 222 | 260 | 337 |
Weight (kg) | 4.13 | 5.33 | 6.60 | 10.05 |
Models
Accessories
For groups of units of any one size up to a total of 400 watts. Do not mix T-Series with Standard Range ventilating units on one controller.
Designed specifically for the Lo-Carbon product range. This self programming electronic On/Off wall mounted humidity sensor reacts to any rapid increase in humidity and temperature by switching a VentAxia fan ‘On’ for rapid removal of moisture laden air in domestic bathrooms and kitchens. Night time relative humidity increment setback feature suppresses nuisance tripping when the humidity level gradually rises as the temperature falls.
- Pullcord override and neon indicator.
- Changeover relay switch.
- Operating range: 30%-90%RH.
- Ambient operating temperature +5°C to +40°C.
- Dimensions: 87 x 87 x 33mm (H x W x D).
- Will fit single gang box for surface mounting.
Automatically reacts to the deterioration of air quality, sensing tobacco smoke, smells and toilet odours to regulate mechanically ventilated areas, such as cinemas, pubs, clubs, restaurants, kitchens, toilets and conference rooms. The sensor switches when the air quality declines below an adjustable preset level. This is registered by a self-cleaning ceramic sensing head. The air quality sensor should not be used for the detection of combustible gases. Ambient operating temperature range 0°C to +50°C. MIN - MAX mode or direct Damper control. Dimensions:87 x 157 x 47mm (H xWxD) Surface mounted. 1 - 25 min O/R timer. Supply voltage 24V DC SELV.
Humidity Control is automatic and can be set to switch between 65 and 90%RH. An integral pullcord provides a manual override function if required. Can be wired for either ON/OFF or Trickle Boost operation. Set Point adjustable. Maximum switching load 1 amp inductive. Pullcord override indicator Ambient operating temperature 0°C to +40°C. Dimensions:87 x 87 x 33mm (H x W x D). Supply voltage 24V DC SELV. Humidity sensors should be sited approx. 100mm below ceiling level and not above cupboards, refer to siting details in fitting and wiring instructions supplied with product.