Traditional T-Series- Darkroom Fan

  •  Extract/intake models in 4 sizes: 6”, 7”, 9” and 12”
  •  Specially designed to provide extract/intake ventilation in darkrooms, X-ray areas, etc
  •  Patented electronic shutter system ensures quiet, trouble free operation
  •  For the very best from your fan use the Ecotronic controller
  •  Integrated component design allows all parts to be dismantled for cleaning without  the use of specialist tools
  •  Easy fit connector Top Socket, standard on all models

Select a product

UK’s No. 1 Commercial Fan

A range designed for photographic, medical, dental and veterinarian applications - used also for opticians and other specialist applications. Most darkrooms need a minimum of ten air changes per hour for comfort and efficiency. For rooms containing heat producing equipment (eg: print glazers) a higher rate of air change may be desirable. The Darkroom fitting kit has two cowls, the interior cowl being designed to give light protection. It can be installed in windows, partitions, external walls or roofs. Extended fixing rods for fixing thicknesses up to 370mm are supplied with the unit. Provision should be made for adequate air replacement through Vent-Axia non-vision grilles.

Shutter

With energy savings in mind Darkroom models are supplied complete with an integral instantaneous automatic louvre shutter concealed behind the interior cowl. Operates on intake and extract at any angle of mounting.

When used with a T-Series or Ecotronic controller, the shutter can be set open with the fan motor switched Off to provide natural ventilation without the security risk of an open window.

Top Socket

A connector Top Socket is standard on all T-Series fans. Allowing fast and trouble-free mains connection.

Electrical

Suitable for running at any angle. Quiet running, enclosed. Fitted with Standard Thermal Overload Protection (S.T.O.P.).

Supply voltage: 220-240V/1/50Hz.

Suitable for operation in ambient temperatures from -40°C to +50°C.

DIMENSIONS:

Size 6 (150mm) 7 (190mm) 9 (230mm) 12 (300mm)
A 100 136 136 171
B 196 206 229 308
C 285 400 400 500
D 220 258 302 378
E 226 265 304 381
F 19 19 19 19
Fixing Hole Diameter 184 222 260 337
Weight (kg) 4.13 5.33 6.60 10.05
 
Image of TX6DR
TX6DR
A range designed for photographic, medical, dental and veterinarian applications - used also for opticians and other specialist applications. Most darkrooms need a minimum of ten air changes per hour for comfort and efficiency. For rooms containing heat producing equipment (eg: print glazers) a higher rate of air change may be desirable. The Darkroom model has two cowls, the interior cowl being designed to give light protection. It can be installed in windows, partitions, external walls or roofs. Extended fixing rods for fixing thicknesses up to 370mm are supplied with the unit. Provision should be made for adequate air replacement through Vent-Axia non-vision grilles. For areas requiring total light exclusion, contact your local Vent-Axia Sales Office. Shutter With energy savings in mind TX models are supplied complete with an integral instantaneous automatic louvre shutter concealed behind the interior cowl. Operates on intake and extract at any angle of mounting. The shutter is electronically controlled by an actuator with a damped action giving quiet operation during instant opening and closing. The interlocking edges of the shutter blades provide maximum backdraught protection. When used with a T-Series controller, the shutter can be set open with the fan motor switched Off to provide natural ventilation without the security risk of an open window. TL models do not have a shutter. They are suitable for room to room systems and where there is a need for ventilation of specialised equipment. The TL model will also provide natural ventilation where required when the unit is switched Off. Suitable for operation in ambient temperatures from -40°C to +50°C.
Stock Ref. No: W161240
(Please call 0344 856 0590 0344 856 0590 for further availability information)
Image of TX7DR
TX7DR
A range designed for photographic, medical, dental and veterinarian applications - used also for opticians and other specialist applications. Most darkrooms need a minimum of ten air changes per hour for comfort and efficiency. For rooms containing heat producing equipment (eg: print glazers) a higher rate of air change may be desirable. The Darkroom model has two cowls, the interior cowl being designed to give light protection. It can be installed in windows, partitions, external walls or roofs. Extended fixing rods for fixing thicknesses up to 370mm are supplied with the unit. Provision should be made for adequate air replacement through Vent-Axia non-vision grilles. For areas requiring total light exclusion, contact your local Vent-Axia Sales Office. Shutter With energy savings in mind TX models are supplied complete with an integral instantaneous automatic louvre shutter concealed behind the interior cowl. Operates on intake and extract at any angle of mounting. The shutter is electronically controlled by an actuator with a damped action giving quiet operation during instant opening and closing. The interlocking edges of the shutter blades provide maximum backdraught protection. When used with a T-Series controller, the shutter can be set open with the fan motor switched Off to provide natural ventilation without the security risk of an open window. TL models do not have a shutter. They are suitable for room to room systems and where there is a need for ventilation of specialised equipment. The TL model will also provide natural ventilation where required when the unit is switched Off. Suitable for operation in ambient temperatures from -40°C to +50°C.
Stock Ref. No: W162240
Price £848.71 (excl VAT)
(Please call 0344 856 0590 0344 856 0590 for further availability information)
Image of TX9DR
TX9DR
A range designed for photographic, medical, dental and veterinarian applications - used also for opticians and other specialist applications. Most darkrooms need a minimum of ten air changes per hour for comfort and efficiency. For rooms containing heat producing equipment (eg: print glazers) a higher rate of air change may be desirable. The Darkroom model has two cowls, the interior cowl being designed to give light protection. It can be installed in windows, partitions, external walls or roofs. Extended fixing rods for fixing thicknesses up to 370mm are supplied with the unit. Provision should be made for adequate air replacement through Vent-Axia non-vision grilles. For areas requiring total light exclusion, contact your local Vent-Axia Sales Office. Shutter With energy savings in mind TX models are supplied complete with an integral instantaneous automatic louvre shutter concealed behind the interior cowl. Operates on intake and extract at any angle of mounting. The shutter is electronically controlled by an actuator with a damped action giving quiet operation during instant opening and closing. The interlocking edges of the shutter blades provide maximum backdraught protection. When used with a T-Series controller, the shutter can be set open with the fan motor switched Off to provide natural ventilation without the security risk of an open window. TL models do not have a shutter. They are suitable for room to room systems and where there is a need for ventilation of specialised equipment. The TL model will also provide natural ventilation where required when the unit is switched Off. Suitable for operation in ambient temperatures from -40°C to +50°C.
Stock Ref. No: W163240
Price £994.57 (excl VAT)
(Please call 0344 856 0590 0344 856 0590 for further availability information)
Image of TX12DR
TX12DR
A range designed for photographic, medical, dental and veterinarian applications - used also for opticians and other specialist applications. Most darkrooms need a minimum of ten air changes per hour for comfort and efficiency. For rooms containing heat producing equipment (eg: print glazers) a higher rate of air change may be desirable. The Darkroom model has two cowls, the interior cowl being designed to give light protection. It can be installed in windows, partitions, external walls or roofs. Extended fixing rods for fixing thicknesses up to 370mm are supplied with the unit. Provision should be made for adequate air replacement through Vent-Axia non-vision grilles. For areas requiring total light exclusion, contact your local Vent-Axia Sales Office. Shutter With energy savings in mind TX models are supplied complete with an integral instantaneous automatic louvre shutter concealed behind the interior cowl. Operates on intake and extract at any angle of mounting. The shutter is electronically controlled by an actuator with a damped action giving quiet operation during instant opening and closing. The interlocking edges of the shutter blades provide maximum backdraught protection. When used with a T-Series controller, the shutter can be set open with the fan motor switched Off to provide natural ventilation without the security risk of an open window. TL models do not have a shutter. They are suitable for room to room systems and where there is a need for ventilation of specialised equipment. The TL model will also provide natural ventilation where required when the unit is switched Off. Suitable for operation in ambient temperatures from -40°C to +50°C.
Stock Ref. No: W164240
Price £1362.53 (excl VAT)
(Please call 0344 856 0590 0344 856 0590 for further availability information)
Image of Ecotronic Controller
Ecotronic Controller

For groups of units of any one size up to a total of 400 watts. Do not mix T-Series with Standard Range ventilating units on one controller.

Stock Ref. No: W362320
Price £260.45 (excl VAT)
Image of Ambient Response Humidity Sensor Lo-Carbon
Ambient Response Humidity Sensor Lo-Carbon

Designed specifically for the Lo-Carbon product range. This self programming electronic On/Off wall mounted humidity sensor reacts to any rapid increase in humidity and temperature by switching a VentAxia fan ‘On’ for rapid removal of moisture laden air in domestic bathrooms and kitchens. Night time relative humidity increment setback feature suppresses nuisance tripping when the humidity level gradually rises as the temperature falls.

  • Pullcord override and neon indicator.
  • Changeover relay switch.
  • Operating range: 30%-90%RH.
  • Ambient operating temperature +5°C to +40°C.
  • Dimensions: 87 x 87 x 33mm (H x W x D).
  • Will fit single gang box for surface mounting.
Stock Ref. No: 563552
Price £340.97 (excl VAT)
Image of Air Quality Sensor (AQS)
Air Quality Sensor (AQS)

Automatically reacts to the deterioration of air quality, sensing tobacco smoke, smells and toilet odours to regulate mechanically ventilated areas, such as cinemas, pubs, clubs, restaurants, kitchens, toilets and conference rooms. The sensor switches when the air quality declines below an adjustable preset level. This is registered by a self-cleaning ceramic sensing head. The air quality sensor should not be used for the detection of combustible gases. Ambient operating temperature range 0°C to +50°C. MIN - MAX mode or direct Damper control. Dimensions:87 x 157 x 47mm (H xWxD) Surface mounted. 1 - 25 min O/R timer. Supply voltage 24V DC SELV.

Stock Ref. No: 432953
Price £371.83 (excl VAT)
(Please call 0344 856 0590 0344 856 0590 for further availability information)
Image of Ecotronic Humidity Sensor (Sentinel)
Ecotronic Humidity Sensor (Sentinel)

Humidity Control is automatic and can be set to switch between 65 and 90%RH. An integral pullcord provides a manual override function if required. Can be wired for either ON/OFF or Trickle Boost operation. Set Point adjustable. Maximum switching load 1 amp inductive. Pullcord override indicator Ambient operating temperature 0°C to +40°C. Dimensions:87 x 87 x 33mm (H x W x D). Supply voltage 24V DC SELV. Humidity sensors should be sited approx. 100mm below ceiling level and not above cupboards, refer to siting details in fitting and wiring instructions supplied with product.

Stock Ref. No: 432949
Price £185.42 (excl VAT)
(Please call 0344 856 0590 0344 856 0590 for further availability information)
Image of Air Quality Sensor
Air Quality Sensor
Automatically reacts to the depletion of air quality, sensing tobacco smoke, smells and toilet odours to regulate mechanically ventilated areas such as cinemas, pubs, clubs, restaurants, kitchens, toilets and conference rooms. The sensor switches the fan On when the air quality declines below an adjustable preset level. This is registered by the ceramic sensing head which is self-cleansing, a process which occurs every time the unit is triggered. When the atmosphere has returned to normal, the fan will continue to run for a pre-set period (adjustable between 1-25 minutes) and then switch Off. The air quality sensor should not be used for the detection of combustible gases and is not designed for use as a smoke detector in an alarm system. The AQS is compatible with T-Series, Multi-Unit, Rangemaster, Ecotronic and TimeSwitch controllers. Features & Benefits: Ambient operating temp range 0°C to +40°C. DEMKO Approved. Dimensions: 87 x 157 x 47mm (H x W x D). Supply voltage 220-240V/1/50Hz Surface mounted. Downloads Catalogue Pages
Stock Ref. No: 563506
Price £394.16 (excl VAT)

 

Raadpleeg de tab Downloads voor technische informatie

 

 

ESTIMATED RUNNING COSTS

Calculate estimated running costs for this product using the tool below.
For average costs*, leave the default values in place or enter your own figures in the boxes to recalculate.
Where a product has multi speeds, a typical installation has been used for the below calculations. *Running cost does not include the use of the heater on the heater model


pence
(Your current electricity cost in pence per hour. This will be listed on your electric bill)
hours
(The average number of hours per day fan to run in Trickle mode)
hours
(The average number of hours per day fan to run in Boost mode)

Based on the inputted figures, estimated running costs would be:

Overview

UK’s No. 1 Commercial Fan

A range designed for photographic, medical, dental and veterinarian applications - used also for opticians and other specialist applications. Most darkrooms need a minimum of ten air changes per hour for comfort and efficiency. For rooms containing heat producing equipment (eg: print glazers) a higher rate of air change may be desirable. The Darkroom fitting kit has two cowls, the interior cowl being designed to give light protection. It can be installed in windows, partitions, external walls or roofs. Extended fixing rods for fixing thicknesses up to 370mm are supplied with the unit. Provision should be made for adequate air replacement through Vent-Axia non-vision grilles.

Shutter

With energy savings in mind Darkroom models are supplied complete with an integral instantaneous automatic louvre shutter concealed behind the interior cowl. Operates on intake and extract at any angle of mounting.

When used with a T-Series or Ecotronic controller, the shutter can be set open with the fan motor switched Off to provide natural ventilation without the security risk of an open window.

Top Socket

A connector Top Socket is standard on all T-Series fans. Allowing fast and trouble-free mains connection.

Electrical

Suitable for running at any angle. Quiet running, enclosed. Fitted with Standard Thermal Overload Protection (S.T.O.P.).

Supply voltage: 220-240V/1/50Hz.

Suitable for operation in ambient temperatures from -40°C to +50°C.

Technical

DIMENSIONS:

Size 6 (150mm) 7 (190mm) 9 (230mm) 12 (300mm)
A 100 136 136 171
B 196 206 229 308
C 285 400 400 500
D 220 258 302 378
E 226 265 304 381
F 19 19 19 19
Fixing Hole Diameter 184 222 260 337
Weight (kg) 4.13 5.33 6.60 10.05
 

Models

Image of TX6DR
TX6DR
A range designed for photographic, medical, dental and veterinarian applications - used also for opticians and other specialist applications. Most darkrooms need a minimum of ten air changes per hour for comfort and efficiency. For rooms containing heat producing equipment (eg: print glazers) a higher rate of air change may be desirable. The Darkroom model has two cowls, the interior cowl being designed to give light protection. It can be installed in windows, partitions, external walls or roofs. Extended fixing rods for fixing thicknesses up to 370mm are supplied with the unit. Provision should be made for adequate air replacement through Vent-Axia non-vision grilles. For areas requiring total light exclusion, contact your local Vent-Axia Sales Office. Shutter With energy savings in mind TX models are supplied complete with an integral instantaneous automatic louvre shutter concealed behind the interior cowl. Operates on intake and extract at any angle of mounting. The shutter is electronically controlled by an actuator with a damped action giving quiet operation during instant opening and closing. The interlocking edges of the shutter blades provide maximum backdraught protection. When used with a T-Series controller, the shutter can be set open with the fan motor switched Off to provide natural ventilation without the security risk of an open window. TL models do not have a shutter. They are suitable for room to room systems and where there is a need for ventilation of specialised equipment. The TL model will also provide natural ventilation where required when the unit is switched Off. Suitable for operation in ambient temperatures from -40°C to +50°C.
Stock Ref. No: W161240
(Please call 0344 856 0590 0344 856 0590 for further availability information)
Image of TX7DR
TX7DR
A range designed for photographic, medical, dental and veterinarian applications - used also for opticians and other specialist applications. Most darkrooms need a minimum of ten air changes per hour for comfort and efficiency. For rooms containing heat producing equipment (eg: print glazers) a higher rate of air change may be desirable. The Darkroom model has two cowls, the interior cowl being designed to give light protection. It can be installed in windows, partitions, external walls or roofs. Extended fixing rods for fixing thicknesses up to 370mm are supplied with the unit. Provision should be made for adequate air replacement through Vent-Axia non-vision grilles. For areas requiring total light exclusion, contact your local Vent-Axia Sales Office. Shutter With energy savings in mind TX models are supplied complete with an integral instantaneous automatic louvre shutter concealed behind the interior cowl. Operates on intake and extract at any angle of mounting. The shutter is electronically controlled by an actuator with a damped action giving quiet operation during instant opening and closing. The interlocking edges of the shutter blades provide maximum backdraught protection. When used with a T-Series controller, the shutter can be set open with the fan motor switched Off to provide natural ventilation without the security risk of an open window. TL models do not have a shutter. They are suitable for room to room systems and where there is a need for ventilation of specialised equipment. The TL model will also provide natural ventilation where required when the unit is switched Off. Suitable for operation in ambient temperatures from -40°C to +50°C.
Stock Ref. No: W162240
Price £848.71 (excl VAT)
(Please call 0344 856 0590 0344 856 0590 for further availability information)
Image of TX9DR
TX9DR
A range designed for photographic, medical, dental and veterinarian applications - used also for opticians and other specialist applications. Most darkrooms need a minimum of ten air changes per hour for comfort and efficiency. For rooms containing heat producing equipment (eg: print glazers) a higher rate of air change may be desirable. The Darkroom model has two cowls, the interior cowl being designed to give light protection. It can be installed in windows, partitions, external walls or roofs. Extended fixing rods for fixing thicknesses up to 370mm are supplied with the unit. Provision should be made for adequate air replacement through Vent-Axia non-vision grilles. For areas requiring total light exclusion, contact your local Vent-Axia Sales Office. Shutter With energy savings in mind TX models are supplied complete with an integral instantaneous automatic louvre shutter concealed behind the interior cowl. Operates on intake and extract at any angle of mounting. The shutter is electronically controlled by an actuator with a damped action giving quiet operation during instant opening and closing. The interlocking edges of the shutter blades provide maximum backdraught protection. When used with a T-Series controller, the shutter can be set open with the fan motor switched Off to provide natural ventilation without the security risk of an open window. TL models do not have a shutter. They are suitable for room to room systems and where there is a need for ventilation of specialised equipment. The TL model will also provide natural ventilation where required when the unit is switched Off. Suitable for operation in ambient temperatures from -40°C to +50°C.
Stock Ref. No: W163240
Price £994.57 (excl VAT)
(Please call 0344 856 0590 0344 856 0590 for further availability information)
Image of TX12DR
TX12DR
A range designed for photographic, medical, dental and veterinarian applications - used also for opticians and other specialist applications. Most darkrooms need a minimum of ten air changes per hour for comfort and efficiency. For rooms containing heat producing equipment (eg: print glazers) a higher rate of air change may be desirable. The Darkroom model has two cowls, the interior cowl being designed to give light protection. It can be installed in windows, partitions, external walls or roofs. Extended fixing rods for fixing thicknesses up to 370mm are supplied with the unit. Provision should be made for adequate air replacement through Vent-Axia non-vision grilles. For areas requiring total light exclusion, contact your local Vent-Axia Sales Office. Shutter With energy savings in mind TX models are supplied complete with an integral instantaneous automatic louvre shutter concealed behind the interior cowl. Operates on intake and extract at any angle of mounting. The shutter is electronically controlled by an actuator with a damped action giving quiet operation during instant opening and closing. The interlocking edges of the shutter blades provide maximum backdraught protection. When used with a T-Series controller, the shutter can be set open with the fan motor switched Off to provide natural ventilation without the security risk of an open window. TL models do not have a shutter. They are suitable for room to room systems and where there is a need for ventilation of specialised equipment. The TL model will also provide natural ventilation where required when the unit is switched Off. Suitable for operation in ambient temperatures from -40°C to +50°C.
Stock Ref. No: W164240
Price £1362.53 (excl VAT)
(Please call 0344 856 0590 0344 856 0590 for further availability information)

Accessories

Image of Ecotronic Controller
Ecotronic Controller

For groups of units of any one size up to a total of 400 watts. Do not mix T-Series with Standard Range ventilating units on one controller.

Stock Ref. No: W362320
Price £260.45 (excl VAT)
Image of Ambient Response Humidity Sensor Lo-Carbon
Ambient Response Humidity Sensor Lo-Carbon

Designed specifically for the Lo-Carbon product range. This self programming electronic On/Off wall mounted humidity sensor reacts to any rapid increase in humidity and temperature by switching a VentAxia fan ‘On’ for rapid removal of moisture laden air in domestic bathrooms and kitchens. Night time relative humidity increment setback feature suppresses nuisance tripping when the humidity level gradually rises as the temperature falls.

  • Pullcord override and neon indicator.
  • Changeover relay switch.
  • Operating range: 30%-90%RH.
  • Ambient operating temperature +5°C to +40°C.
  • Dimensions: 87 x 87 x 33mm (H x W x D).
  • Will fit single gang box for surface mounting.
Stock Ref. No: 563552
Price £340.97 (excl VAT)
Image of Air Quality Sensor (AQS)
Air Quality Sensor (AQS)

Automatically reacts to the deterioration of air quality, sensing tobacco smoke, smells and toilet odours to regulate mechanically ventilated areas, such as cinemas, pubs, clubs, restaurants, kitchens, toilets and conference rooms. The sensor switches when the air quality declines below an adjustable preset level. This is registered by a self-cleaning ceramic sensing head. The air quality sensor should not be used for the detection of combustible gases. Ambient operating temperature range 0°C to +50°C. MIN - MAX mode or direct Damper control. Dimensions:87 x 157 x 47mm (H xWxD) Surface mounted. 1 - 25 min O/R timer. Supply voltage 24V DC SELV.

Stock Ref. No: 432953
Price £371.83 (excl VAT)
(Please call 0344 856 0590 0344 856 0590 for further availability information)
Image of Ecotronic Humidity Sensor (Sentinel)
Ecotronic Humidity Sensor (Sentinel)

Humidity Control is automatic and can be set to switch between 65 and 90%RH. An integral pullcord provides a manual override function if required. Can be wired for either ON/OFF or Trickle Boost operation. Set Point adjustable. Maximum switching load 1 amp inductive. Pullcord override indicator Ambient operating temperature 0°C to +40°C. Dimensions:87 x 87 x 33mm (H x W x D). Supply voltage 24V DC SELV. Humidity sensors should be sited approx. 100mm below ceiling level and not above cupboards, refer to siting details in fitting and wiring instructions supplied with product.

Stock Ref. No: 432949
Price £185.42 (excl VAT)
(Please call 0344 856 0590 0344 856 0590 for further availability information)
Image of Air Quality Sensor
Air Quality Sensor
Automatically reacts to the depletion of air quality, sensing tobacco smoke, smells and toilet odours to regulate mechanically ventilated areas such as cinemas, pubs, clubs, restaurants, kitchens, toilets and conference rooms. The sensor switches the fan On when the air quality declines below an adjustable preset level. This is registered by the ceramic sensing head which is self-cleansing, a process which occurs every time the unit is triggered. When the atmosphere has returned to normal, the fan will continue to run for a pre-set period (adjustable between 1-25 minutes) and then switch Off. The air quality sensor should not be used for the detection of combustible gases and is not designed for use as a smoke detector in an alarm system. The AQS is compatible with T-Series, Multi-Unit, Rangemaster, Ecotronic and TimeSwitch controllers. Features & Benefits: Ambient operating temp range 0°C to +40°C. DEMKO Approved. Dimensions: 87 x 157 x 47mm (H x W x D). Supply voltage 220-240V/1/50Hz Surface mounted. Downloads Catalogue Pages
Stock Ref. No: 563506
Price £394.16 (excl VAT)

Downloads