Super T-series - Heavy Duty Wall Fans
• 4 impeller diameters 355, 400, 450, 500mm
• Complete with telescopic wall sleeve and shutter, ready for installation
• IP54 motor and terminal box
• Smart internal grille and external shutter with flange trim
• Super quiet operation
• For the very best performance from your fan, use the Vent-Axia 25 Amp electronic controller
Select a product
Powerful Ventilation
Vent-Axia’s Super T-Series 355, 400, 450 and 500mm fans provide efficient, quiet powerful ventilation with performances up to 4940m3 /h. Tough heavy duty internal grilles and external weather shutters ensure longevity, performance and peace of mind.
Construction
The axial fan at the heart of the Super T range is based on an integrated impeller and internal rotor motor design which produces a very compact unit. A specially designed bellmouth inlet and mounting plate ensures an excellent performance to sound level ratio.
Electrical
Single phase 220-240V 50Hz. Capacitor start and run. An IP54 terminal box is supplied with all models with conduit entry from the side of the wall liner. All motors are fitted with Standard Thermal Overload Protection (S.T.O.P.), which should be wired via the controller.
DIMENSIONS:
Impeller dia. | 355 | 400 | 450 | 500 |
A | 550 | 597 | 657 | 727 |
B | 550 | 597 | 657 | 727 |
C | 470 | 520 | 580 | 650 |
D | 470 | 520 | 580 | 650 |
Weight (kg) | 17 | 22 | 28 | 33 |
--- | ||||
Impeller dia. | 355 | 400 | ||
A | 552 | 640 | ||
B | 520 | 622 | ||
C | 390 | 440 | ||
D | 100 | 100 | ||
E | 364 | 420 | ||
F | 520 | 622 | ||
G | 436 | 486 | ||
H | 81 | 70 | ||
Super T - Gravity shutters Extract model incorporating gravity shutter and internal grille. When installed only the room side aluminium fascia grille is visible. The outside is finished with an external gravity shutter and frame.
For applications where regular switching is required at fixed periods or at different times on different days of the week, eg: offices, shops, pubs and restaurants.
The 7-day TimeSwitch gives twelve On or Off positions per day and can be set for 7 days. The cycle will repeat until changed.
- Analogue clock display and integral time switches for ease of setting.
- Manual override.
- Removable clear plastic cover protects TimeSwitch face.
- Volt free changeover contacts.
- Time base: 7 days.
- Shortest switching time: 2 hours.
- Maximum load: 16amp resistive (8amp inductive).
- Ambient operating temperature range -20°C to +85°C.
- Dimensions: 104 x 74 x 52mm (H x W x D).
- Supply voltage 220-240V/1/50Hz
Suitable for controlling a range of Vent-Axia fans. Continuously monitors an area and activates when a moving body is detected.
- Supplied complete with wall mounting bracket.
- Adjustable timer overrun (5 seconds to 20 minutes).
- Supplied with lens to provide 15m (max) range, 200° detection area.
- Designed to meet IP55.
- Ambient operating temperature range -20°C to +50°C.
- Maximum load: 10 amp resistive (5 amp inductive).
- Suitable for use with fluorescent lighting up to 500W.
- Internal/External use.
- Supply voltage 220-240V/1/50Hz.
Raadpleeg de tab Downloads voor technische informatie
ESTIMATED RUNNING COSTS
Calculate estimated running costs for this product using the tool below.
For average costs*, leave the default values in place or enter your own figures in the boxes to recalculate.
Where a product has multi speeds, a typical installation has been used for the below calculations. *Running cost does not include the use of the heater on the heater model
Based on the inputted figures, estimated running costs would be:
Overview
Powerful Ventilation
Vent-Axia’s Super T-Series 355, 400, 450 and 500mm fans provide efficient, quiet powerful ventilation with performances up to 4940m3 /h. Tough heavy duty internal grilles and external weather shutters ensure longevity, performance and peace of mind.
Construction
The axial fan at the heart of the Super T range is based on an integrated impeller and internal rotor motor design which produces a very compact unit. A specially designed bellmouth inlet and mounting plate ensures an excellent performance to sound level ratio.
Electrical
Single phase 220-240V 50Hz. Capacitor start and run. An IP54 terminal box is supplied with all models with conduit entry from the side of the wall liner. All motors are fitted with Standard Thermal Overload Protection (S.T.O.P.), which should be wired via the controller.
Technical
DIMENSIONS:
Impeller dia. | 355 | 400 | 450 | 500 |
A | 550 | 597 | 657 | 727 |
B | 550 | 597 | 657 | 727 |
C | 470 | 520 | 580 | 650 |
D | 470 | 520 | 580 | 650 |
Weight (kg) | 17 | 22 | 28 | 33 |
--- | ||||
Impeller dia. | 355 | 400 | ||
A | 552 | 640 | ||
B | 520 | 622 | ||
C | 390 | 440 | ||
D | 100 | 100 | ||
E | 364 | 420 | ||
F | 520 | 622 | ||
G | 436 | 486 | ||
H | 81 | 70 | ||
Models
Super T - Gravity shutters Extract model incorporating gravity shutter and internal grille. When installed only the room side aluminium fascia grille is visible. The outside is finished with an external gravity shutter and frame.
Accessories
For applications where regular switching is required at fixed periods or at different times on different days of the week, eg: offices, shops, pubs and restaurants.
The 7-day TimeSwitch gives twelve On or Off positions per day and can be set for 7 days. The cycle will repeat until changed.
- Analogue clock display and integral time switches for ease of setting.
- Manual override.
- Removable clear plastic cover protects TimeSwitch face.
- Volt free changeover contacts.
- Time base: 7 days.
- Shortest switching time: 2 hours.
- Maximum load: 16amp resistive (8amp inductive).
- Ambient operating temperature range -20°C to +85°C.
- Dimensions: 104 x 74 x 52mm (H x W x D).
- Supply voltage 220-240V/1/50Hz
Suitable for controlling a range of Vent-Axia fans. Continuously monitors an area and activates when a moving body is detected.
- Supplied complete with wall mounting bracket.
- Adjustable timer overrun (5 seconds to 20 minutes).
- Supplied with lens to provide 15m (max) range, 200° detection area.
- Designed to meet IP55.
- Ambient operating temperature range -20°C to +50°C.
- Maximum load: 10 amp resistive (5 amp inductive).
- Suitable for use with fluorescent lighting up to 500W.
- Internal/External use.
- Supply voltage 220-240V/1/50Hz.