HR500 & HR500X
Efficient 153 l/s heat recovery ventilation unit or high performance 250 l/s extract fan
Lightweight, compact and easy to install
Integral Shutters on X type model
Up to 70% heat recovery
Easy to clean
Controller with sensor mode, allows a range of sensors to be used in conjunction with the HR500 and HR500X units
Select a product
Heat recovery ventilation unit for through the wall installation which exhausts stale air whilst introducing warmed fresh air from the outside. As a heat recovery ventilation unit it moves a useful 153 l/s of air. This unit is fully speed controllable with the facility to reverse the supply air fan and provide 'double extraction' for periods when heat loss is desirable.
The unit is the perfect solution to commercial areas that require a high performance balanced intake/extract scheme. Ideal for swimming pools, computer rooms, classrooms, offices and the health and leisure industries. In noise sensitive areas use an auto transformer controller.
Installation
The unit should be ducted to atmosphere using an integral wall liner and should fit wall thicknesses between 450 and 670mm and should have washable reticulated foam filters provided in the supply and extract airflows.
Sound Power Level Spectra dB (re10-¹²Watts)
Frequency (Hz)
63
125
250
500
1K
2K
4K
8K
Heat Recovery Mode
67
76
75
74
67
60
51
38
Extract Only Mode
(Both fans)
66
76
76
74
67
60
51
37
Power Consumption
Supply fan
60W
Extract fan
150W
HR500 Controller (Surface Mounted)
With knockouts for recessed wiring or surface wiring. An optional flush fitting box is available. Requires 5-core cable.
One controller will operate a maximum of 2 HR500 or HR500X units.
On/Off/Sensor mode.
Choice of heat exchange or high/low speed extract fan mode.
Infinitely variable speed control from low to high.
Adjustable minimum speed.
With integral thermal cut-out and circuit fuse protection.
PERFORMANCE:
Graph:
DIMENSIONS:
HR 500: 16kg
HR 500X: 19kg



For flush fitting a metal wall box accessory is available for use with the surface mounting model for conduit connection. Hole for wall box: 80 x 150 x 50mm (H x W x D).


With knockouts for recessed wiring or surface wiring. An optional flush fitting box is available. Requires 5-core cable. One controller will operate a maximum of 2 HR500 or HR500X units. On/Off/Sensor mode. Choice of heat exchange or high/low speed extract fan mode. Infinitely variable speed control from low to high. Adjustable minimum speed. With integral thermal cut-out and circuit fuse protection.
Raadpleeg de tab Downloads voor technische informatie
ESTIMATED RUNNING COSTS
Calculate estimated running costs for this product using the tool below.
For average costs*, leave the default values in place or enter your own figures in the boxes to recalculate.
Where a product has multi speeds, a typical installation has been used for the below calculations. *Running cost does not include the use of the heater on the heater model
Based on the inputted figures, estimated running costs would be:
Overview
Heat recovery ventilation unit for through the wall installation which exhausts stale air whilst introducing warmed fresh air from the outside. As a heat recovery ventilation unit it moves a useful 153 l/s of air. This unit is fully speed controllable with the facility to reverse the supply air fan and provide 'double extraction' for periods when heat loss is desirable.
The unit is the perfect solution to commercial areas that require a high performance balanced intake/extract scheme. Ideal for swimming pools, computer rooms, classrooms, offices and the health and leisure industries. In noise sensitive areas use an auto transformer controller.
Installation
The unit should be ducted to atmosphere using an integral wall liner and should fit wall thicknesses between 450 and 670mm and should have washable reticulated foam filters provided in the supply and extract airflows.
Sound Power Level Spectra dB (re10-¹²Watts)
Frequency (Hz)
63
125
250
500
1K
2K
4K
8K
Heat Recovery Mode
67
76
75
74
67
60
51
38
Extract Only Mode
(Both fans)
66
76
76
74
67
60
51
37
Power Consumption
Supply fan
60W
Extract fan
150W
HR500 Controller (Surface Mounted)
With knockouts for recessed wiring or surface wiring. An optional flush fitting box is available. Requires 5-core cable.
One controller will operate a maximum of 2 HR500 or HR500X units.
On/Off/Sensor mode.
Choice of heat exchange or high/low speed extract fan mode.
Infinitely variable speed control from low to high.
Adjustable minimum speed.
With integral thermal cut-out and circuit fuse protection.
Technical
PERFORMANCE:
Graph:
DIMENSIONS:
HR 500: 16kg
HR 500X: 19kg
Models


Accessories

For flush fitting a metal wall box accessory is available for use with the surface mounting model for conduit connection. Hole for wall box: 80 x 150 x 50mm (H x W x D).


With knockouts for recessed wiring or surface wiring. An optional flush fitting box is available. Requires 5-core cable. One controller will operate a maximum of 2 HR500 or HR500X units. On/Off/Sensor mode. Choice of heat exchange or high/low speed extract fan mode. Infinitely variable speed control from low to high. Adjustable minimum speed. With integral thermal cut-out and circuit fuse protection.