EuroSeries (ESR) - Roof Mounting Axial Fans

 

  • Cowl & base moulded from recyclable polymeric material 
  • All sizes resistant to UV light
  • Sizes 250 to 1000 dia are protected to IP54
  • Optional backdraught shutters and bird guard (250-630mm)
  • All models speed controllable
  • Motor Insulation Class F, -40°C to +70°C operating temperature
  • Reversible for supply or extract units
  • Thermal overload for motor protection
  • Performance tested to BS848 part 1 1980
  • Designed for Data Centre and Warehouse cooling

A range of extract axial blade industrial roof fans incorporating the Euroseries® ESP axial plate fan, featuring a single shot die cast aluminium blade & external rotor motor design.

Cowl and roof mounting base are moulded from specially formulated recyclable polymeric materials, which are high impact resistant and provide a rigid profile against strong winds and resistance to UV light. Standard colour BS00A05.

EuroSeries® ESR units are suitable for flat or inclined roofs (max. angle 30°) and are designed for either kerb or purlin box mounting.

The EuroSeries® ESR range is available in eleven sizes with the extract performances up to 10.88m³/s, with pressure characteristics of up 300Pa. All units are designed for & fully speed controllable.

Air Operated Shutters & Bird Guards

The shutters fits beneath the cowl using fitting provided. Shutters should not be used when the fan performance is below 30% of maximum and the hinge should point up the roof incline.

The standard shutters for sizes 800 & 1000mm must not be used with 4 & 6 pole unit. Please enquire for special metal shutters. Bird Guards are manufactured to fit neatly between the roof cowl and the base.

Impellers

All sizes are supplied with cast aluminium impellers, ensuring performance when working against outdoor conditions and abrasive airflow. All fans are reversible for Intake (approx 30% reduction in performance). Backdraught shutters should not be used when operated as an intake fan.

Motors

External rotor motors are specially designed and styled for this range of fan. Ball bearings are greased for life. Rotors are dynamically balanced to ISO 1940. Sizes 250-1000mm, motors are protected to IP54, against dust and moisture complying with BS EN 60529:1992. They are ribbed aluminium body castings for efficient cooling. Motor insulation is Class ‘F’ (from -40°C to +70°C).

Electrical

Single phase 220-240V 50Hz. Capacitor start and run. Three phase 380-415V 50Hz. An IP54 terminal box is supplied with most models with 20mm and PGII entry. All motors are fitted with thermal overload protection which should be wired into all controller circuits and into starter contactors. Models are available with either 2,4, 6 & 8 pole motors.

Terminal Box

Are to IP54, as standard, protected against dust and water from any angle allowing outside applications.

Performance

The fan performance is in accordance with tests to BS848 Part 1 1980.

Sound Levels

Fan sound levels, measured in a reverberant chamber in accordance with BS848 Part 2 1985. Published dB(A) figures are free field sound pressure levels at 3m with spherical propagation at a reference level of 2 x 10-5 Pa (20 micro-Pascal). The sound power level spectra figures are dB with reference level of 10-12 Watts (1 pico-watt). To ensure minimum noise levels during speed control, an auto transformer speed control is recommended.

DIMENSIONS:

Size a b c d e f Kg max
250 700 475 737 411 97 675 13.25
315 700 475 737 411 97 675 16.30
355 700 475 737 411 97 675 16.30
400 800 575 830 466 97 775 18.40
450 800 575 830 466 97 775 20.30
500 950 715 1000 579 100 915 35.50
560 950 715 1000 579 100 915 35.50
630 1230 840 1100 731 105 1040 62.00
710 1230 840 1100 731 105 1040 62.00
800 1420 870 1190 731 105 1070 78.00
1000 1680 1070 1455 795 131 1270 134

 

Raadpleeg de tab Downloads voor technische informatie

 

 

ESTIMATED RUNNING COSTS

Calculate estimated running costs for this product using the tool below.
For average costs*, leave the default values in place or enter your own figures in the boxes to recalculate.
Where a product has multi speeds, a typical installation has been used for the below calculations. *Running cost does not include the use of the heater on the heater model


pence
(Your current electricity cost in pence per hour. This will be listed on your electric bill)
hours
(The average number of hours per day fan to run in Trickle mode)
hours
(The average number of hours per day fan to run in Boost mode)

Based on the inputted figures, estimated running costs would be:

Overview

A range of extract axial blade industrial roof fans incorporating the Euroseries® ESP axial plate fan, featuring a single shot die cast aluminium blade & external rotor motor design.

Cowl and roof mounting base are moulded from specially formulated recyclable polymeric materials, which are high impact resistant and provide a rigid profile against strong winds and resistance to UV light. Standard colour BS00A05.

EuroSeries® ESR units are suitable for flat or inclined roofs (max. angle 30°) and are designed for either kerb or purlin box mounting.

The EuroSeries® ESR range is available in eleven sizes with the extract performances up to 10.88m³/s, with pressure characteristics of up 300Pa. All units are designed for & fully speed controllable.

Air Operated Shutters & Bird Guards

The shutters fits beneath the cowl using fitting provided. Shutters should not be used when the fan performance is below 30% of maximum and the hinge should point up the roof incline.

The standard shutters for sizes 800 & 1000mm must not be used with 4 & 6 pole unit. Please enquire for special metal shutters. Bird Guards are manufactured to fit neatly between the roof cowl and the base.

Impellers

All sizes are supplied with cast aluminium impellers, ensuring performance when working against outdoor conditions and abrasive airflow. All fans are reversible for Intake (approx 30% reduction in performance). Backdraught shutters should not be used when operated as an intake fan.

Motors

External rotor motors are specially designed and styled for this range of fan. Ball bearings are greased for life. Rotors are dynamically balanced to ISO 1940. Sizes 250-1000mm, motors are protected to IP54, against dust and moisture complying with BS EN 60529:1992. They are ribbed aluminium body castings for efficient cooling. Motor insulation is Class ‘F’ (from -40°C to +70°C).

Electrical

Single phase 220-240V 50Hz. Capacitor start and run. Three phase 380-415V 50Hz. An IP54 terminal box is supplied with most models with 20mm and PGII entry. All motors are fitted with thermal overload protection which should be wired into all controller circuits and into starter contactors. Models are available with either 2,4, 6 & 8 pole motors.

Terminal Box

Are to IP54, as standard, protected against dust and water from any angle allowing outside applications.

Performance

The fan performance is in accordance with tests to BS848 Part 1 1980.

Sound Levels

Fan sound levels, measured in a reverberant chamber in accordance with BS848 Part 2 1985. Published dB(A) figures are free field sound pressure levels at 3m with spherical propagation at a reference level of 2 x 10-5 Pa (20 micro-Pascal). The sound power level spectra figures are dB with reference level of 10-12 Watts (1 pico-watt). To ensure minimum noise levels during speed control, an auto transformer speed control is recommended.

Technical

DIMENSIONS:

Size a b c d e f Kg max
250 700 475 737 411 97 675 13.25
315 700 475 737 411 97 675 16.30
355 700 475 737 411 97 675 16.30
400 800 575 830 466 97 775 18.40
450 800 575 830 466 97 775 20.30
500 950 715 1000 579 100 915 35.50
560 950 715 1000 579 100 915 35.50
630 1230 840 1100 731 105 1040 62.00
710 1230 840 1100 731 105 1040 62.00
800 1420 870 1190 731 105 1070 78.00
1000 1680 1070 1455 795 131 1270 134

Downloads