Lo-Carbon Sentinel Kinetic Horizontal
- Manufactured in the UK
- Building Regulation ADF compliant
- Recognised in SAP PCDB
- Energy Savings Trust best practice compliant
- Up to 81% heat recovery whilst controlling condensation
- Programmable Summer bypass
- Digital controller for simple and accurate commissioning
- External condensate connection
- Plug and play controls; Humidistat, Ventwise
- LS inputs (Light Switch)
- Self diagnosis for simplified fault finding
- Adjustable delay on/delay off timer
Select a product
The Sentinel Kinetic Horizontal Range
A wholehouse heat recovery system with up to 81% heat exchange efficiency. An easily accessible heat recovery cube protected by two removable ISO 45% Coarse (G3) Filter 2pk.
Incorporating two Lo-Carbon Energy Saving EC/DC motors ensures long life (typically over double the life of AC motors) and lowest possible energy use.
Fully insulated construction with built in condensation drain. Specifically designed for new build constructions with a high level of insulation.
The Lo-Carbon Sentinel Kinetic Horizontal meets the latest requirements of the Building Regulations ADF for wholehouse system ventilation: Continuous mechanical supply and extract with heat recovery.
The Lo-Carbon Sentinel Kinetic Horizontal models have three fully adjustable speeds and a purge setting (maximum airflow). Supplied with the unit is a digital controller that can be used to pre-set the speeds to any required airflow within the performance range.
Integral Humidity Sensor
The integral humidity sensor ('H' models) increases speed in proportion to relative humidity levels, saving energy and reducing noise. The sensor also reacts to small but rapid increases in humidity, even if the normal trigger threshold is not reached. This unique feature ensures adequate ventilation, even for the smallest wet-room. The night-time relative humidity setback feature suppresses nuisance tripping as humidity gradually increases with falling temperature. Acoustically lined - low noise levels from on 20 dB(A) @ 3m.
Multiple control options
Five volt-free pairs of switch terminals for sensor inputs allow boosting from a full range of Vent-Axia controllers - humidistats, PIR, timers.
Two terminals with 0-24V outputs allow 0V to 10V proportional control by sophisticated controllers such as CO2 sensors and proportional humidistats.
Switch-live for boosting via light switches (220-240V AC) or manual Normal/Boost switches. This connection has the advantage of Delay-On and Delay-Off facility. Delay-On enables you to prevent the Boost airflow between 0 and10 minutes after a light switch has been activated. Delay-Off allows the Boostairflow to continue after a light switch is turned off to ensure effective clearanceof humidity. This timer is adjustable between 0 and 25 minutes.
Summer Bypass
An internal damper is activated when the outside temperature is less than the room temperature. The damper opens allowing cooler fresh air to bypass the Heat Recovery Cell and reduce the internal temperature towards the pre-set 'Comfort Temperature'. When the inside air temperature reaches the pre-set 'Comfort Temperature' the bypass damper closes.
Evening Purge mode: The fans run on Boost speed until the internal temperature falls below the set 'Indoor' temperature. If, after five hours the internal temperature is still above the set 'Indoor' temperature, the unit will switch down to normal speed for the remainder of the 'bypass
open' period. Night-time Purge mode: As Evening Purge, except that the unit will continue on Boost speed until the internal air temperature reaches the 'Outdoor' temperatureset point (Default 14°C). This mode gives pre-cooling of the dwelling for the
following day. In Evening and Night Time Purge modes, the user can turn off the boost function by pressing the Boost button.
Frost Protection
In cold climates there is a possibility of frost building up on the intake side of the heat exchanger. In order to prevent damage, the Kinetic reduces supply flow while maintaining extract flow at temperature down to -20°C.
Supply and install a Sentinel Kinetic Horizontal system Wholehouse heat recovery unit as manufactured by:
Vent-Axia
Fleming Way
Crawley West
Sussex
RH10 9YX
Performance:
m³/h
l/s
Max ventilation rate
191 (270) at 150Pa
53 (75)
N° speed settings
3 (variable between 10% and 100%)
(300Z in brackets)
Efficiency: The unit should retain up to 79% of the temperature differential of out going air.
Heat exchanger: should be of a multi plate counter-flow type constructed out of aluminium.
Motor: should be a Lowatt Energy Saving DC with ball bearings, greased for life. It shall operate up to an ambient temperature of 40°C and be fitted with an electronic thermal overload protective device.
Fan: The fan impeller should be of a backward curved centrifugal type, dynamically balanced.
Ducting spigots: The unit should provide 125mm ø x 50mm long spigots (200Z) or 150mm ø x 50mm long spigots (300Z)for duct connections. (Can be converted to flat ducting).
Filter: should be synthetic material tested to minimum of EU3.
Condensation: The outlet provided should offer connection within the overall depth of the unit.
Construction: The unit outer case should be constructed of galvanised steel. The heat exchanger access doors should give tool-free access to the filters.
Mounting: Horizontal, slab mounting with access from below..
Mains electrical supply: 230VAC 50Hz.
Complies to the following approvals/directives: CE, LVD, EMC.
Click here for technical information, within our Online Product Selector. After, select your required fan model from the list to display Performance, Sound, Dimensions and Electrical Data.
PRODUCT SPECIFICATION:
The Lo-Carbon Sentinel Kinetic Horizontal models have 2 fully adjustable speeds and a purge setting - maximum. Supplied with the unit is a digital controller that can be used to pre-set the speeds to any required air-flow within the performance range.
The Sentinel Kinetic Horizontal models designed to be horizontally mounted under a slab, with access for servicing and maintenance from below. When mounted in an unheated area ducting must be insulated. 200 Z models are 200mm deep, including condensate and mounting bracket.
300 Z models are 300mm deep, including condensate and mounting bracket.
Condensate drain is through the 'atmosphere' end of the unit. Using the fittings supplied, the final condensate connection is made outside the unit and can be completed after installation.
Electrical and control connections are also made on the outside of the unit.
PERFORMANCE:
DIMENSIONS:
Weight: 200Z: 26kg 300Z: 38kg
High efficiency, compact, horizontal, residential Mechanical Ventilation with Heat Recovery unit (humidity sensor version)
High efficiency, compact, horizontal, residential Mechanical Ventilation with Heat Recovery unit (humidity sensor version)
High efficiency, compact, horizontal, residential Mechanical Ventilation with Heat Recovery unit (humidity sensor version).
Replacement filter comprising one supply filter for the Kinetic B, BH and Cooker hood units. Pack contains one M5 Pollen filter. M5 provides increased performance filtering out most pollens. Installation instructions included.
This item is no longer available. Please use 444199
Replacement filter (pack of 2) for the Sentinel Kinetic Horizontal 200ZP, 200ZPH and 200ZPM
Replacement filter (pack of 2) for the Sentinel Kinetic Horizontal 200Z and 200ZH
Replacement filters (pack of 2) G3 for the Sentinel Kinetic Horizontal 300Z and 300ZH
Replacement single M5 Supply Filter for the Sentinel Kinetic 200Z/200ZH/200ZMH
Replacement single M5 Supply Filter for the Sentinel Kinetic Horizontal 300Z and 300ZH
The Wireless enable kit allows the Kinetic to be set to boost or purge from a remote wireless switch. One switch is supplied with the kit. Up to three additional switches may be linked to the wireless receiver.
- Additional controller for Wireless enable kit and Wireless Transmitter Controller Receiver Kit
- A maximum of 4 controllers can be used per system
- Can be connected to other accessories (eg Humidistat) to send a boost signal wirelessly
IMPORTANT – This wireless controller is not compatible with any new Sentinel Multivent Ranges (white units). It is only compatible with these Sentinel Multivent part numbers; 445655, 445655A & 407849.
The award wining Vent Wise controller has been designed to fully automate a ventilation system. The unit can be used to switch the unit between trickle and boost speed. The controller saves energy by only switching when cooking is taking place or condensation is being generated. The current sensor detects when the power supply to an oven or hob is switched on. The temperature sensor detects the rise in temperature in the hot feed to a bath or shower. A combination of up to three sensors may be used with one controller This controller consists of a small pcb which is plugged onto the control board alongside the terminal connectors. This converts switches 1 to 3 into sensor inputs. A combination of up to three current and/or temperature sensors can then be connected.
Raadpleeg de tab Downloads voor technische informatie
ESTIMATED RUNNING COSTS
Calculate estimated running costs for this product using the tool below.
For average costs*, leave the default values in place or enter your own figures in the boxes to recalculate.
Where a product has multi speeds, a typical installation has been used for the below calculations. *Running cost does not include the use of the heater on the heater model
Based on the inputted figures, estimated running costs would be:
Overview
The Sentinel Kinetic Horizontal Range
A wholehouse heat recovery system with up to 81% heat exchange efficiency. An easily accessible heat recovery cube protected by two removable ISO 45% Coarse (G3) Filter 2pk.
Incorporating two Lo-Carbon Energy Saving EC/DC motors ensures long life (typically over double the life of AC motors) and lowest possible energy use.
Fully insulated construction with built in condensation drain. Specifically designed for new build constructions with a high level of insulation.
The Lo-Carbon Sentinel Kinetic Horizontal meets the latest requirements of the Building Regulations ADF for wholehouse system ventilation: Continuous mechanical supply and extract with heat recovery.
The Lo-Carbon Sentinel Kinetic Horizontal models have three fully adjustable speeds and a purge setting (maximum airflow). Supplied with the unit is a digital controller that can be used to pre-set the speeds to any required airflow within the performance range.
Integral Humidity Sensor
The integral humidity sensor ('H' models) increases speed in proportion to relative humidity levels, saving energy and reducing noise. The sensor also reacts to small but rapid increases in humidity, even if the normal trigger threshold is not reached. This unique feature ensures adequate ventilation, even for the smallest wet-room. The night-time relative humidity setback feature suppresses nuisance tripping as humidity gradually increases with falling temperature. Acoustically lined - low noise levels from on 20 dB(A) @ 3m.
Multiple control options
Five volt-free pairs of switch terminals for sensor inputs allow boosting from a full range of Vent-Axia controllers - humidistats, PIR, timers.
Two terminals with 0-24V outputs allow 0V to 10V proportional control by sophisticated controllers such as CO2 sensors and proportional humidistats.
Switch-live for boosting via light switches (220-240V AC) or manual Normal/Boost switches. This connection has the advantage of Delay-On and Delay-Off facility. Delay-On enables you to prevent the Boost airflow between 0 and10 minutes after a light switch has been activated. Delay-Off allows the Boostairflow to continue after a light switch is turned off to ensure effective clearanceof humidity. This timer is adjustable between 0 and 25 minutes.
Summer Bypass
An internal damper is activated when the outside temperature is less than the room temperature. The damper opens allowing cooler fresh air to bypass the Heat Recovery Cell and reduce the internal temperature towards the pre-set 'Comfort Temperature'. When the inside air temperature reaches the pre-set 'Comfort Temperature' the bypass damper closes.
Evening Purge mode: The fans run on Boost speed until the internal temperature falls below the set 'Indoor' temperature. If, after five hours the internal temperature is still above the set 'Indoor' temperature, the unit will switch down to normal speed for the remainder of the 'bypass
open' period. Night-time Purge mode: As Evening Purge, except that the unit will continue on Boost speed until the internal air temperature reaches the 'Outdoor' temperatureset point (Default 14°C). This mode gives pre-cooling of the dwelling for the
following day. In Evening and Night Time Purge modes, the user can turn off the boost function by pressing the Boost button.
Frost Protection
In cold climates there is a possibility of frost building up on the intake side of the heat exchanger. In order to prevent damage, the Kinetic reduces supply flow while maintaining extract flow at temperature down to -20°C.
Supply and install a Sentinel Kinetic Horizontal system Wholehouse heat recovery unit as manufactured by:
Vent-Axia
Fleming Way
Crawley West
Sussex
RH10 9YX
Performance:
m³/h
l/s
Max ventilation rate
191 (270) at 150Pa
53 (75)
N° speed settings
3 (variable between 10% and 100%)
(300Z in brackets)
Efficiency: The unit should retain up to 79% of the temperature differential of out going air.
Heat exchanger: should be of a multi plate counter-flow type constructed out of aluminium.
Motor: should be a Lowatt Energy Saving DC with ball bearings, greased for life. It shall operate up to an ambient temperature of 40°C and be fitted with an electronic thermal overload protective device.
Fan: The fan impeller should be of a backward curved centrifugal type, dynamically balanced.
Ducting spigots: The unit should provide 125mm ø x 50mm long spigots (200Z) or 150mm ø x 50mm long spigots (300Z)for duct connections. (Can be converted to flat ducting).
Filter: should be synthetic material tested to minimum of EU3.
Condensation: The outlet provided should offer connection within the overall depth of the unit.
Construction: The unit outer case should be constructed of galvanised steel. The heat exchanger access doors should give tool-free access to the filters.
Mounting: Horizontal, slab mounting with access from below..
Mains electrical supply: 230VAC 50Hz.
Complies to the following approvals/directives: CE, LVD, EMC.
Technical
Click here for technical information, within our Online Product Selector. After, select your required fan model from the list to display Performance, Sound, Dimensions and Electrical Data.
PRODUCT SPECIFICATION:
The Lo-Carbon Sentinel Kinetic Horizontal models have 2 fully adjustable speeds and a purge setting - maximum. Supplied with the unit is a digital controller that can be used to pre-set the speeds to any required air-flow within the performance range.
The Sentinel Kinetic Horizontal models designed to be horizontally mounted under a slab, with access for servicing and maintenance from below. When mounted in an unheated area ducting must be insulated. 200 Z models are 200mm deep, including condensate and mounting bracket.
300 Z models are 300mm deep, including condensate and mounting bracket.
Condensate drain is through the 'atmosphere' end of the unit. Using the fittings supplied, the final condensate connection is made outside the unit and can be completed after installation.
Electrical and control connections are also made on the outside of the unit.
PERFORMANCE:
DIMENSIONS:
Weight: 200Z: 26kg 300Z: 38kg
Models
High efficiency, compact, horizontal, residential Mechanical Ventilation with Heat Recovery unit (humidity sensor version)
High efficiency, compact, horizontal, residential Mechanical Ventilation with Heat Recovery unit (humidity sensor version)
High efficiency, compact, horizontal, residential Mechanical Ventilation with Heat Recovery unit (humidity sensor version).
Replacement filter comprising one supply filter for the Kinetic B, BH and Cooker hood units. Pack contains one M5 Pollen filter. M5 provides increased performance filtering out most pollens. Installation instructions included.
This item is no longer available. Please use 444199
Accessories
Replacement filter (pack of 2) for the Sentinel Kinetic Horizontal 200ZP, 200ZPH and 200ZPM
Replacement filter (pack of 2) for the Sentinel Kinetic Horizontal 200Z and 200ZH
Replacement filters (pack of 2) G3 for the Sentinel Kinetic Horizontal 300Z and 300ZH
Replacement single M5 Supply Filter for the Sentinel Kinetic 200Z/200ZH/200ZMH
Replacement single M5 Supply Filter for the Sentinel Kinetic Horizontal 300Z and 300ZH
The Wireless enable kit allows the Kinetic to be set to boost or purge from a remote wireless switch. One switch is supplied with the kit. Up to three additional switches may be linked to the wireless receiver.
- Additional controller for Wireless enable kit and Wireless Transmitter Controller Receiver Kit
- A maximum of 4 controllers can be used per system
- Can be connected to other accessories (eg Humidistat) to send a boost signal wirelessly
IMPORTANT – This wireless controller is not compatible with any new Sentinel Multivent Ranges (white units). It is only compatible with these Sentinel Multivent part numbers; 445655, 445655A & 407849.
The award wining Vent Wise controller has been designed to fully automate a ventilation system. The unit can be used to switch the unit between trickle and boost speed. The controller saves energy by only switching when cooking is taking place or condensation is being generated. The current sensor detects when the power supply to an oven or hob is switched on. The temperature sensor detects the rise in temperature in the hot feed to a bath or shower. A combination of up to three sensors may be used with one controller This controller consists of a small pcb which is plugged onto the control board alongside the terminal connectors. This converts switches 1 to 3 into sensor inputs. A combination of up to three current and/or temperature sensors can then be connected.