Lo-Carbon Kinetic Plus E
• Acoustic Enclosure option for reduced breakout noise
• Acoustic Top Box option for reduced in-duct noise
• Lightweight for easy installation
• Easy access filters
• External condensate connection
• Compatible with a range of controls: PIR, Humidistat
• Horizontal duct option for space-saving installations
• Up to 94% heat recovery
• Summer mode
• Manufactured in the UK
• Switched live inputs (Light switch control)
Select a product
A wholehouse heat recovery system with up to 94% energy efficiency. An easily accessible heat recovery cube protected by two removableISO 45% Coarse (G3) Filters. Two Lo-Carbon Energy Saving EC/DC fans ensure long life (typically over double the life of AC motors) and lowest possible energy use. Fully insulated construction with built-in condensation drain.
Lo-Carbon Kinetic Plus E meets the latest requirements of the Building Regulations Approved Document F for wholehouse system ventilation.
The Lo-Carbon Kinetic Plus E model has two adjustable speeds, normal and boost. On the front of the unit is the controller that can be used to preset the speeds to any required performance, up to 111l/s (400m3/hr) 150Pa. Offering ‘Close Control’ to prevent over ventilating.
Acoustically lined - low noise levels from only 20dB(A) @ 3m.
For scenarios where noise is a critical issue, an Acoustic Enclosure is available to reduce breakout noise and the Acoustic Top Box will reduce in-duct noise at key frequencies.
Left or Right Hand Installation
Units are supplied right handed with duct spigots to outside on the right hand side. These can be reversed onsite by simply removing the control panel, rotating the unit 180 degrees and reattaching the control panel.
Spigot Options
The combination of spigot options allows installation in confined locations. If vertical and horizontal connections are required on the same outlet/inlet, additional spigots can be supplied.
Filter Check
An LED on the control panel illuminates at 6 month intervals to remind
users to check and clean the filters.
Frost Protection
The Kinetic E range benefits from an automatic frost protection system to prevent the heat recovery cell freezing in very cold weather, while at the same time maintaining ventilation.
Control Options
There are two LS (Switched Live) inputs allowing the unit to be connected to a number of sensors and controllers such as Timespan, Ambient Response Humidistat. One of the LS connections also benefits from a ‘Delay-On’ feature which prevents the unit boosting unnecessarily.
Switching on the control panel allows activation of the Summer Mode.
Acoustic Solution
This product is available with acoustic enclosure. For more info please click here.
PERFORMANCE:
Click here for technical information, within our Online Product Selector. After, select your required fan model from the list to display Performance, Sound, Dimensions and Electrical Data

High efficiency, SAP Appendix Q eligable, residential Mechanical Ventilation with Heat Recovery unit

The Acoustic Enclosure reduces breakout noise from the MVHR unit, ensuring occupants are not disturbed by system noise throughout the dwelling. It features internal anti-vibration mounts which prevent vibration passing from the unit through the fabric of the building. The Acoustic Top Box reduces in-duct noise in living areas, bedrooms and wet rooms. It also provides a neat enclosure for ductwork at the point of installation.

The Acoustic Top Box reduces in-duct noise in living areas, bedrooms and wet rooms. It also provides a neat enclosure for ductwork at the point of installation

The Acoustic Enclosure reduces breakout noise from the MVHR unit, ensuring occupants are not disturbed by system noise throughout the dwelling. It features internal anti-vibration mounts which prevent vibration passing from the unit through the fabric of the building.


ISO ePM10 50% (M5) Filter 1 Pack. Formally known as M5, this filter will remove smaller particles, including pollen.

Sentinel Kinetic Advance Standard Filter - ISO 45% Course (G3) Filter 2 Pack. Formally known as G3, this filter will provide the minimum required filtration.
Raadpleeg de tab Downloads voor technische informatie
ESTIMATED RUNNING COSTS
Calculate estimated running costs for this product using the tool below.
For average costs*, leave the default values in place or enter your own figures in the boxes to recalculate.
Where a product has multi speeds, a typical installation has been used for the below calculations. *Running cost does not include the use of the heater on the heater model
Based on the inputted figures, estimated running costs would be:
Overview
A wholehouse heat recovery system with up to 94% energy efficiency. An easily accessible heat recovery cube protected by two removableISO 45% Coarse (G3) Filters. Two Lo-Carbon Energy Saving EC/DC fans ensure long life (typically over double the life of AC motors) and lowest possible energy use. Fully insulated construction with built-in condensation drain.
Lo-Carbon Kinetic Plus E meets the latest requirements of the Building Regulations Approved Document F for wholehouse system ventilation.
The Lo-Carbon Kinetic Plus E model has two adjustable speeds, normal and boost. On the front of the unit is the controller that can be used to preset the speeds to any required performance, up to 111l/s (400m3/hr) 150Pa. Offering ‘Close Control’ to prevent over ventilating.
Acoustically lined - low noise levels from only 20dB(A) @ 3m.
For scenarios where noise is a critical issue, an Acoustic Enclosure is available to reduce breakout noise and the Acoustic Top Box will reduce in-duct noise at key frequencies.
Left or Right Hand Installation
Units are supplied right handed with duct spigots to outside on the right hand side. These can be reversed onsite by simply removing the control panel, rotating the unit 180 degrees and reattaching the control panel.
Spigot Options
The combination of spigot options allows installation in confined locations. If vertical and horizontal connections are required on the same outlet/inlet, additional spigots can be supplied.
Filter Check
An LED on the control panel illuminates at 6 month intervals to remind
users to check and clean the filters.
Frost Protection
The Kinetic E range benefits from an automatic frost protection system to prevent the heat recovery cell freezing in very cold weather, while at the same time maintaining ventilation.
Control Options
There are two LS (Switched Live) inputs allowing the unit to be connected to a number of sensors and controllers such as Timespan, Ambient Response Humidistat. One of the LS connections also benefits from a ‘Delay-On’ feature which prevents the unit boosting unnecessarily.
Switching on the control panel allows activation of the Summer Mode.
Acoustic Solution
This product is available with acoustic enclosure. For more info please click here.
Technical
PERFORMANCE:
Click here for technical information, within our Online Product Selector. After, select your required fan model from the list to display Performance, Sound, Dimensions and Electrical Data
Models

High efficiency, SAP Appendix Q eligable, residential Mechanical Ventilation with Heat Recovery unit

The Acoustic Enclosure reduces breakout noise from the MVHR unit, ensuring occupants are not disturbed by system noise throughout the dwelling. It features internal anti-vibration mounts which prevent vibration passing from the unit through the fabric of the building. The Acoustic Top Box reduces in-duct noise in living areas, bedrooms and wet rooms. It also provides a neat enclosure for ductwork at the point of installation.

The Acoustic Top Box reduces in-duct noise in living areas, bedrooms and wet rooms. It also provides a neat enclosure for ductwork at the point of installation

The Acoustic Enclosure reduces breakout noise from the MVHR unit, ensuring occupants are not disturbed by system noise throughout the dwelling. It features internal anti-vibration mounts which prevent vibration passing from the unit through the fabric of the building.
Accessories


ISO ePM10 50% (M5) Filter 1 Pack. Formally known as M5, this filter will remove smaller particles, including pollen.

Sentinel Kinetic Advance Standard Filter - ISO 45% Course (G3) Filter 2 Pack. Formally known as G3, this filter will provide the minimum required filtration.