Lo-Carbon Multivent MVDC-MS / MSH
Please click here for the latest product alternative.
- Recognised in SAP PCDB with best in class Specific Fan Power
- Reduces your carbon footprint
- Fitted with four extract 125 diameter spigots allowing quick
- connection to ducts
- Complies with Building ADF (System 3)
- Option of wall, ceiling and loft mounting
- Improved controllability
- Switched Live Boost connection
- Fully variable normal and boost speeds
- Ultra quiet - acoustically lined for low noise levels
- Integral humidistat (H version)
With growing concerns about accurate ventilation of properties, the Lo- Carbon Multivent MVDC range offers the option of ‘Close Control’ both in the residential and the commercial sectors. With a DC motor the multi speed Lo-Carbon Multivent is one of the most efficient central extract units available.
The units have two fully variable speeds for trickle and boost, with a switched live (LS) activation for the boost speed. An additional third speed (purge) is available using a second switched live connection.
The potentiometer controlled speed selector allows accurate setting of airflow, ensuring exactly the right ventilation rate. This feature also reduces noise, and energy consumption.
DIMENSIONS:
Dimensions (mm)
A | B | C | D | E | F | G | H | I | J |
340 | 72.5 | 25 | 15 | 360 | 214 | 310 | 249 | 150 | 85 |
With the growing concerns about over ventilating properties, the Multivent MVDC MS offers the option of ‘Close Control’ both in the residential and the commercial sectors. With a DC motor the Multispeed Multivent is one of the most efficient central extract units in the UK. The unit has 2 fully variable speeds for trickle and boost, with a switched live (LS) activation for the boost speed. An additional third speed (purge) is available using a second switched live connection.
The Multivent continuous mechanical extract ventilation range is designed for the simultaneous ventilation of separate areas in the home or as a multi-point extractor system for a wide range of commercial applications. With a DC motor the Multispeed Multivent is one of the most efficient central extract units in the UK. The Multivent MVDC MSH offers the option of ‘Close Control’ both in the residential and the commercial sectors with the added benefit of an inbuilt humidistat. The unit has 2 fully variable speeds for trickle and boost, with an inbuilt humidistat activation for the boost speed. A switched live (LS) can also be used to select boost speed when wired through an Isolator Relay (Part No. 442030 - not supplied). An additional third speed (purge) is available using a second switched live connection. Extended guarantee to 5 years offered on the MVDC LoWatt energy saving motor.
A wall or ceiling mounted movement detector for use with any domestic Vent-Axia mains voltage product. Also suitable for use with Vent-Axia T-Series controllers on ‘Auto’ setting and ITC controllers on sensor mode. Visionex PIR can be wired for either On/Off or Trickle/ Boost operation.
- Fits any UK single gang mounting box.
- Adjustable timer overrun (5-25 minutes).
- Range of detection up to 10 metres.
- Designed to meet IP43.
- Ambient operating temperature range 0°C to +50°C.
- Maximum load: 2.5 amps/600W inductive. Not suitable for use with lighting.
- Internal use only.
- No switched live required for internal rooms and WCs.
- Double insulated.
- Volt-free contacts.
- Supply voltage 220-240V/1/50Hz.
Designed specifically for the Lo-Carbon product range. This self programming electronic On/Off wall mounted humidity sensor reacts to any rapid increase in humidity and temperature by switching a VentAxia fan ‘On’ for rapid removal of moisture laden air in domestic bathrooms and kitchens. Night time relative humidity increment setback feature suppresses nuisance tripping when the humidity level gradually rises as the temperature falls.
- Pullcord override and neon indicator.
- Changeover relay switch.
- Operating range: 30%-90%RH.
- Ambient operating temperature +5°C to +40°C.
- Dimensions: 87 x 87 x 33mm (H x W x D).
- Will fit single gang box for surface mounting.
Humidity Control is automatic and can be set to switch between 65 and 90%RH. An integral pullcord provides a manual override function if required. Can be wired for either ON/OFF or Trickle Boost operation. Set Point adjustable. Maximum switching load 1 amp inductive. Pullcord override indicator Ambient operating temperature 0°C to +40°C. Dimensions:87 x 87 x 33mm (H x W x D). Supply voltage 24V DC SELV. Humidity sensors should be sited approx. 100mm below ceiling level and not above cupboards, refer to siting details in fitting and wiring instructions supplied with product.
3D REVIT FILES:
Raadpleeg de tab Downloads voor technische informatie
ESTIMATED RUNNING COSTS
Calculate estimated running costs for this product using the tool below.
For average costs*, leave the default values in place or enter your own figures in the boxes to recalculate.
Where a product has multi speeds, a typical installation has been used for the below calculations. *Running cost does not include the use of the heater on the heater model
Based on the inputted figures, estimated running costs would be:
Overview
With growing concerns about accurate ventilation of properties, the Lo- Carbon Multivent MVDC range offers the option of ‘Close Control’ both in the residential and the commercial sectors. With a DC motor the multi speed Lo-Carbon Multivent is one of the most efficient central extract units available.
The units have two fully variable speeds for trickle and boost, with a switched live (LS) activation for the boost speed. An additional third speed (purge) is available using a second switched live connection.
The potentiometer controlled speed selector allows accurate setting of airflow, ensuring exactly the right ventilation rate. This feature also reduces noise, and energy consumption.
Technical
DIMENSIONS:
Dimensions (mm)
A | B | C | D | E | F | G | H | I | J |
340 | 72.5 | 25 | 15 | 360 | 214 | 310 | 249 | 150 | 85 |
Models
With the growing concerns about over ventilating properties, the Multivent MVDC MS offers the option of ‘Close Control’ both in the residential and the commercial sectors. With a DC motor the Multispeed Multivent is one of the most efficient central extract units in the UK. The unit has 2 fully variable speeds for trickle and boost, with a switched live (LS) activation for the boost speed. An additional third speed (purge) is available using a second switched live connection.
The Multivent continuous mechanical extract ventilation range is designed for the simultaneous ventilation of separate areas in the home or as a multi-point extractor system for a wide range of commercial applications. With a DC motor the Multispeed Multivent is one of the most efficient central extract units in the UK. The Multivent MVDC MSH offers the option of ‘Close Control’ both in the residential and the commercial sectors with the added benefit of an inbuilt humidistat. The unit has 2 fully variable speeds for trickle and boost, with an inbuilt humidistat activation for the boost speed. A switched live (LS) can also be used to select boost speed when wired through an Isolator Relay (Part No. 442030 - not supplied). An additional third speed (purge) is available using a second switched live connection. Extended guarantee to 5 years offered on the MVDC LoWatt energy saving motor.
Accessories
A wall or ceiling mounted movement detector for use with any domestic Vent-Axia mains voltage product. Also suitable for use with Vent-Axia T-Series controllers on ‘Auto’ setting and ITC controllers on sensor mode. Visionex PIR can be wired for either On/Off or Trickle/ Boost operation.
- Fits any UK single gang mounting box.
- Adjustable timer overrun (5-25 minutes).
- Range of detection up to 10 metres.
- Designed to meet IP43.
- Ambient operating temperature range 0°C to +50°C.
- Maximum load: 2.5 amps/600W inductive. Not suitable for use with lighting.
- Internal use only.
- No switched live required for internal rooms and WCs.
- Double insulated.
- Volt-free contacts.
- Supply voltage 220-240V/1/50Hz.
Designed specifically for the Lo-Carbon product range. This self programming electronic On/Off wall mounted humidity sensor reacts to any rapid increase in humidity and temperature by switching a VentAxia fan ‘On’ for rapid removal of moisture laden air in domestic bathrooms and kitchens. Night time relative humidity increment setback feature suppresses nuisance tripping when the humidity level gradually rises as the temperature falls.
- Pullcord override and neon indicator.
- Changeover relay switch.
- Operating range: 30%-90%RH.
- Ambient operating temperature +5°C to +40°C.
- Dimensions: 87 x 87 x 33mm (H x W x D).
- Will fit single gang box for surface mounting.
Humidity Control is automatic and can be set to switch between 65 and 90%RH. An integral pullcord provides a manual override function if required. Can be wired for either ON/OFF or Trickle Boost operation. Set Point adjustable. Maximum switching load 1 amp inductive. Pullcord override indicator Ambient operating temperature 0°C to +40°C. Dimensions:87 x 87 x 33mm (H x W x D). Supply voltage 24V DC SELV. Humidity sensors should be sited approx. 100mm below ceiling level and not above cupboards, refer to siting details in fitting and wiring instructions supplied with product.