Vent-Axia Pure Air
• Removes NOX and other gases
• Removes particles down to PM2.5
• Offers multiple spigot options
• Low pressure drop
• Easy to install with mounting brackets
• Conforms to international air quality guideline limits
• Easy installation & maintenance
• Various sizes to suit residential or commercial applications
• Provides induct noise attenuation
• Insulating jackets available
• New compact unit available
Select a product
What is it?
The Vent-Axia Pure Air combines particulate and gas filters to remove pollutants prior to entering residences and commercial buildings through mechanical ventilation and heat recovery systems. The Vent-Axia Pure Air is designed to bring outdoor air pollutant levels within the guideline exposure limits as set out in the World Health Organisation Air Quality Guidelines and the CAFE Directive prior to entering an occupied space. Indoor air quality (IAQ) is becoming increasingly important with properties being built in urban, industrialised areas. The Vent-Axia Pure Air offers a complete filtration solution with a range of specifiable products that meet planning obligations and refine traditional filtration, leaving home owners with confidence in their heat recovery systems.
What does it do?
The Vent-Axia Pure Air sets the benchmark for high level filtration. It targets pollutants generated outside of the home, by traffic and industrial processes, and reduces these before supplying the air into the dwelling.
The Vent-Axia Pure Air filter is fitted to the intake airflow and incorporates two types of filtration:
• Enhanced activated Carbon which removes unpleasant odours and harmful gasses such as Nitrous Oxide (NO2 ).
• ISO 65% Coarse (G4) or ePM2.5 (F7) particulate filters which can remove tiny airborne contaminants such as pollen, bacteria and even PM2.5 diesel particulates.
The combination of MVHR and Vent-Axia Pure Air filtration offers the ideal indoor environment.
PRODUCT SPECIFICATION:
Unit Specification
The Vent-Axia Pure Air is manufactured from 1.2mm Galvanised Steel together with suitable sealing for particulate and gas filters. Access is available on both sides via bolted lift off panels. Various round and rectangular transformation spigots are available to suit ductwork systems for both domestic and commercial duct work.
Filter Specification
Particulates, PM10, PM2.5
A new ISO filtration standard has come into force. The test method has changed so direct comparisons between EN779 2012 and ISO 16890 cannot be drawn. Below is a guide to the filter efficiencies:
ISO 16890 EN779
45% Coarse G3
65% Coarse G4
ePM10 50% M5
ePM2.5 70% F7
Pollutant Gases, NO2 , SO2 , O3 , VOC
The gas stage filters in the Vent-Axia Pure Air are designed to achieve a minimum contact time suitable for the removal of pollutant gases at the rated airflow. A specially formulated activated carbon and chemical mix acts upon pollutant concentrations common in dirty city air, reducing them below guidelines set by current legislation.














PDF DOWNLOADS:
Raadpleeg de tab Downloads voor technische informatie
ESTIMATED RUNNING COSTS
Calculate estimated running costs for this product using the tool below.
For average costs*, leave the default values in place or enter your own figures in the boxes to recalculate.
Where a product has multi speeds, a typical installation has been used for the below calculations. *Running cost does not include the use of the heater on the heater model
Based on the inputted figures, estimated running costs would be:
Overview
What is it?
The Vent-Axia Pure Air combines particulate and gas filters to remove pollutants prior to entering residences and commercial buildings through mechanical ventilation and heat recovery systems. The Vent-Axia Pure Air is designed to bring outdoor air pollutant levels within the guideline exposure limits as set out in the World Health Organisation Air Quality Guidelines and the CAFE Directive prior to entering an occupied space. Indoor air quality (IAQ) is becoming increasingly important with properties being built in urban, industrialised areas. The Vent-Axia Pure Air offers a complete filtration solution with a range of specifiable products that meet planning obligations and refine traditional filtration, leaving home owners with confidence in their heat recovery systems.
What does it do?
The Vent-Axia Pure Air sets the benchmark for high level filtration. It targets pollutants generated outside of the home, by traffic and industrial processes, and reduces these before supplying the air into the dwelling.
The Vent-Axia Pure Air filter is fitted to the intake airflow and incorporates two types of filtration:
• Enhanced activated Carbon which removes unpleasant odours and harmful gasses such as Nitrous Oxide (NO2 ).
• ISO 65% Coarse (G4) or ePM2.5 (F7) particulate filters which can remove tiny airborne contaminants such as pollen, bacteria and even PM2.5 diesel particulates.
The combination of MVHR and Vent-Axia Pure Air filtration offers the ideal indoor environment.
Technical
PRODUCT SPECIFICATION:
Unit Specification
The Vent-Axia Pure Air is manufactured from 1.2mm Galvanised Steel together with suitable sealing for particulate and gas filters. Access is available on both sides via bolted lift off panels. Various round and rectangular transformation spigots are available to suit ductwork systems for both domestic and commercial duct work.
Filter Specification
Particulates, PM10, PM2.5
A new ISO filtration standard has come into force. The test method has changed so direct comparisons between EN779 2012 and ISO 16890 cannot be drawn. Below is a guide to the filter efficiencies:
ISO 16890 EN779
45% Coarse G3
65% Coarse G4
ePM10 50% M5
ePM2.5 70% F7
Pollutant Gases, NO2 , SO2 , O3 , VOC
The gas stage filters in the Vent-Axia Pure Air are designed to achieve a minimum contact time suitable for the removal of pollutant gases at the rated airflow. A specially formulated activated carbon and chemical mix acts upon pollutant concentrations common in dirty city air, reducing them below guidelines set by current legislation.

Models