ACM100-200 & ACM250-315
ACM 100-200
- Designed and manufactured in the UK
- Three speed motor
- Timer versions available
- Removable motor core
- Rotating motor chassis
- IP44 rated
- Aesthetically pleasing with wipe clean polymer casing
- Sound data from independent testing
- Running speed selected on installation
ACM 250-315
- Available in two sizes
- Supplied complete for simple installation
- Optimise fan performance by using an approved Vent-Axia controller
- Diagonal impeller with stator
- Galvanized metal housing
- Integrated thermal switch
- Includes a mounting bracket
- Designed to meet IP54
Select a product
Vent Axia has designed a complete range of energy efficient Mixed Flow In-Line fans that are now quieter, offer two and half times the pressure of conventional axial fans and are dimensionally more compact making them ideal for many ducted applications. The ACM Mixed Flow In-Line fan can operate in both horizontal and vertical positions.
Motor
All units have have three speed motors, speed selectable on installation and are fitted with Standard Thermal Overload Protection (S.T.O.P.). Designed for ambient temperatures up to +50°C. All sizes with capacitor run motors. All sizes are Class II appliances. Supply voltage 220-240V/1/50Hz.
Installation
These units have a separate footplate for simple location mounting and detachable spigots for simple connection to ducting. The motor body chassis rotates to provide connection in acute spaces. Cleaning the product has also become simple as all parts can be removed without removing the ducting.
Controller
For optimum variable speed performance use a Vent-Axia 1.5 Amp electronic controller. Surface mounted providing variable speed control with an On/Off/sensor slider with indication light. There is an adjustable minimum speed setting. The controller has electrical connections for use with suitable external sensors. Cannot be used with timer models.
Click here for technical information, within our Online Product Selector. After, select your required fan model from the list to display Performance, Sound, Dimensions and Electrical Data.
ACM In-line Mixed Flow Fans - ACM100 with 100mm diameter spigots
ACM In-line Mixed Flow Fans - ACM100T with 100mm diameter spigots and over run timer
ACM In-line Mixed Flow Fans - ACM125 with 125mm diameter spigots
ACM In-line Mixed Flow Fans - ACM150 with 150mm diameter spigots
ACM In-line Mixed Flow Fans - ACM150 with 150mm diameter spigots and over run timer
ACM In-line Mixed Flow Fans - ACM200 with 200mm diameter spigots
ACM In-line Mixed Flow Fans - ACM200T with 200mm diameter spigots
Surface mounting. It will provide infinitely variable speed control and features an On/Off/sensor slider with neon indicator. There is an adjustable minimum speed setting. The controller is radio suppressed to BS EN 55014 and electrical connections for use with suitable external sensors are provided. 86 x 156 x 53mm (H x W x D). For flush fitting a metal wall box accessory is available. Hole for wall box:80x150x150mm (HxWxD)
For flush fitting a metal wall box accessory is available for use with the surface mounting model for conduit connection. Hole for wall box: 80 x 150 x 50mm (H x W x D).
240VAC 50Hz.
European Patent No: 2298057
A wall or ceiling mounted movement detector for use with any domestic Vent-Axia mains voltage product. Also suitable for use with Vent-Axia T-Series controllers on ‘Auto’ setting and ITC controllers on sensor mode. Visionex PIR can be wired for either On/Off or Trickle/ Boost operation.
- Fits any UK single gang mounting box.
- Adjustable timer overrun (5-25 minutes).
- Range of detection up to 10 metres.
- Designed to meet IP43.
- Ambient operating temperature range 0°C to +50°C.
- Maximum load: 2.5 amps/600W inductive. Not suitable for use with lighting.
- Internal use only.
- No switched live required for internal rooms and WCs.
- Double insulated.
- Volt-free contacts.
- Supply voltage 220-240V/1/50Hz.
Raadpleeg de tab Downloads voor technische informatie
ESTIMATED RUNNING COSTS
Calculate estimated running costs for this product using the tool below.
For average costs*, leave the default values in place or enter your own figures in the boxes to recalculate.
Where a product has multi speeds, a typical installation has been used for the below calculations. *Running cost does not include the use of the heater on the heater model
Based on the inputted figures, estimated running costs would be:
Overview
Vent Axia has designed a complete range of energy efficient Mixed Flow In-Line fans that are now quieter, offer two and half times the pressure of conventional axial fans and are dimensionally more compact making them ideal for many ducted applications. The ACM Mixed Flow In-Line fan can operate in both horizontal and vertical positions.
Motor
All units have have three speed motors, speed selectable on installation and are fitted with Standard Thermal Overload Protection (S.T.O.P.). Designed for ambient temperatures up to +50°C. All sizes with capacitor run motors. All sizes are Class II appliances. Supply voltage 220-240V/1/50Hz.
Installation
These units have a separate footplate for simple location mounting and detachable spigots for simple connection to ducting. The motor body chassis rotates to provide connection in acute spaces. Cleaning the product has also become simple as all parts can be removed without removing the ducting.
Controller
For optimum variable speed performance use a Vent-Axia 1.5 Amp electronic controller. Surface mounted providing variable speed control with an On/Off/sensor slider with indication light. There is an adjustable minimum speed setting. The controller has electrical connections for use with suitable external sensors. Cannot be used with timer models.
Technical
Click here for technical information, within our Online Product Selector. After, select your required fan model from the list to display Performance, Sound, Dimensions and Electrical Data.
Models
ACM In-line Mixed Flow Fans - ACM100 with 100mm diameter spigots
ACM In-line Mixed Flow Fans - ACM100T with 100mm diameter spigots and over run timer
ACM In-line Mixed Flow Fans - ACM125 with 125mm diameter spigots
ACM In-line Mixed Flow Fans - ACM150 with 150mm diameter spigots
ACM In-line Mixed Flow Fans - ACM150 with 150mm diameter spigots and over run timer
ACM In-line Mixed Flow Fans - ACM200 with 200mm diameter spigots
ACM In-line Mixed Flow Fans - ACM200T with 200mm diameter spigots
Accessories
Surface mounting. It will provide infinitely variable speed control and features an On/Off/sensor slider with neon indicator. There is an adjustable minimum speed setting. The controller is radio suppressed to BS EN 55014 and electrical connections for use with suitable external sensors are provided. 86 x 156 x 53mm (H x W x D). For flush fitting a metal wall box accessory is available. Hole for wall box:80x150x150mm (HxWxD)
For flush fitting a metal wall box accessory is available for use with the surface mounting model for conduit connection. Hole for wall box: 80 x 150 x 50mm (H x W x D).
240VAC 50Hz.
European Patent No: 2298057
A wall or ceiling mounted movement detector for use with any domestic Vent-Axia mains voltage product. Also suitable for use with Vent-Axia T-Series controllers on ‘Auto’ setting and ITC controllers on sensor mode. Visionex PIR can be wired for either On/Off or Trickle/ Boost operation.
- Fits any UK single gang mounting box.
- Adjustable timer overrun (5-25 minutes).
- Range of detection up to 10 metres.
- Designed to meet IP43.
- Ambient operating temperature range 0°C to +50°C.
- Maximum load: 2.5 amps/600W inductive. Not suitable for use with lighting.
- Internal use only.
- No switched live required for internal rooms and WCs.
- Double insulated.
- Volt-free contacts.
- Supply voltage 220-240V/1/50Hz.