The ITC model provides automatic changeover on fan failure as well as enabling a manual selection of either fan for duty sharing or test purposes. (BMS compatible via volt free contacts). This controller must have a permanent live supply. Any On/Off switching must be via the sensor connections S1 and SG terminals.
The ITC-DS model (Duty sharing). Incorporates a timing mechanism which operates alternate fans on 12 or 24 hour intervals, thus ensuring the extended life of the fan bearings. The controller also provides automatic changeover on fan failure along with the facility for manual selection of either fan. (BMS compatible via volt free contacts). This controller must have a permanent live supply. Any On/Off switching must be via the sensor connections S1 and SG terminals
The RSC multi-speed control system offers 2 speed fan versatility eg. Energy Management for night-time setback. Can be used in conjunction with Vent-Axia ITC, ITC-DS controllers using 5 step auto-transformer speed controllers for speed selection. Uses 24V output from ITC controller. Dimensions: 86mm x 178mm x 100mm (Width x Height x Depth)
3 amp electronic controllers provide infinitely variable speed control from preset minimum to maximum. Features an On/Off switch with neon indicator and speed control knob. Built in 'Hard Start' auto maximum speed for a few seconds. Dimensions 150mm x 90mm x 65mm (Width x Height x Depth) Weight 0.5kg
6 amp electronic controllers provide infinitely variable speed control from preset minimum to maximum. Features an On/Off switch with neon indicator and speed control knob. Built in 'Hard Start' auto maximum speed for a few seconds. Dimensions 150mm x 90mm x 65mm (Width x Height x Depth) Weight 0.5kg
10 amp electronic controller provides infinitely variable speed control from preset minimum to maximum and feature On/Off Override switch for maximum speed. Neon indicator and built-in 'Hard Start' auto-maximum speed for a few seconds. Dimensions 167mm x 220mm x130mm (width x Height x Depth) Weight 1.3 Kg
For applications where regular switching is required at fixed periods or at different times on different days of the week, eg: offices, shops, pubs and restaurants.
The 7-day TimeSwitch gives twelve On or Off positions per day and can be set for 7 days. The cycle will repeat until changed.
- Analogue clock display and integral time switches for ease of setting.
- Manual override.
- Removable clear plastic cover protects TimeSwitch face.
- Volt free changeover contacts.
- Time base: 7 days.
- Shortest switching time: 2 hours.
- Maximum load: 16amp resistive (8amp inductive).
- Ambient operating temperature range -20°C to +85°C.
- Dimensions: 104 x 74 x 52mm (H x W x D).
- Supply voltage 220-240V/1/50Hz
Humidity Control is automatic and can be set to switch between 65 and 90%RH. An integral pullcord provides a manual override function if required. Can be wired for either ON/OFF or Trickle Boost operation. Set Point adjustable. Maximum switching load 1 amp inductive. Pullcord override indicator Ambient operating temperature 0°C to +40°C. Dimensions:87 x 87 x 33mm (H x W x D). Supply voltage 24V DC SELV. Humidity sensors should be sited approx. 100mm below ceiling level and not above cupboards, refer to siting details in fitting and wiring instructions supplied with product.
Operates Vent-Axia ventilating units on either a rise or a fall in humidity to control the damaging effects of condensation.
- Concealed adjustment.
- Setting range 20% to 80% RH.
- Ambient operating temperature 0°C to +50°C.
- Dimensions: 82 x 132 x 40mm (H x W x D).
- Rating 2A (1A inductive).
- Switching range 120-240V.
- Designed for use with controllers with ‘Auto’ mode facility.
- Single pole changeover contacts.
Automatically reacts to the deterioration of air quality, sensing tobacco smoke, smells and toilet odours to regulate mechanically ventilated areas, such as cinemas, pubs, clubs, restaurants, kitchens, toilets and conference rooms. The sensor switches when the air quality declines below an adjustable preset level. This is registered by a self-cleaning ceramic sensing head. The air quality sensor should not be used for the detection of combustible gases. Ambient operating temperature range 0°C to +50°C. MIN - MAX mode or direct Damper control. Dimensions:87 x 157 x 47mm (H xWxD) Surface mounted. 1 - 25 min O/R timer. Supply voltage 24V DC SELV.
A wall or ceiling mounted movement detector for use with any domestic Vent-Axia mains voltage product. Also suitable for use with Vent-Axia T-Series controllers on ‘Auto’ setting and ITC controllers on sensor mode. Visionex PIR can be wired for either On/Off or Trickle/ Boost operation.
- Fits any UK single gang mounting box.
- Adjustable timer overrun (5-25 minutes).
- Range of detection up to 10 metres.
- Designed to meet IP43.
- Ambient operating temperature range 0°C to +50°C.
- Maximum load: 2.5 amps/600W inductive. Not suitable for use with lighting.
- Internal use only.
- No switched live required for internal rooms and WCs.
- Double insulated.
- Volt-free contacts.
- Supply voltage 220-240V/1/50Hz.
20 amp electronic controller provides infinitely variable speed control from preset minimum to preset maximum via lid mounted potentiometer and features; On/Off Override contacts for remote switching Built-in 'Hard Start' auto-maximum speed for a few seconds. 24V (80mA) supply for remote sensors(lid potentiometer to be disconnected) 0-10v Input for remote sensor Motor Thermal protection connections (TP's) IP rating - IP54 Weight 2.3 Kg
PDF DOWNLOADS:
Raadpleeg de tab Downloads voor technische informatie
ESTIMATED RUNNING COSTS
Calculate estimated running costs for this product using the tool below.
For average costs*, leave the default values in place or enter your own figures in the boxes to recalculate.
Where a product has multi speeds, a typical installation has been used for the below calculations. *Running cost does not include the use of the heater on the heater model
Based on the inputted figures, estimated running costs would be:
Overview
Vent Axia offer a full range of controllers to compliment the Industrial Fan Range.
For controllers matched to specific ventilation Products, please refer to the relevant Fan product page for details.
Technical
Models
Please click here for the latest product alternative
The ITC model provides automatic changeover on fan failure as well as enabling a manual selection of either fan for duty sharing or test purposes. (BMS compatible via volt free contacts). This controller must have a permanent live supply. Any On/Off switching must be via the sensor connections S1 and SG terminals.
The ITC-DS model (Duty sharing). Incorporates a timing mechanism which operates alternate fans on 12 or 24 hour intervals, thus ensuring the extended life of the fan bearings. The controller also provides automatic changeover on fan failure along with the facility for manual selection of either fan. (BMS compatible via volt free contacts). This controller must have a permanent live supply. Any On/Off switching must be via the sensor connections S1 and SG terminals
The RSC multi-speed control system offers 2 speed fan versatility eg. Energy Management for night-time setback. Can be used in conjunction with Vent-Axia ITC, ITC-DS controllers using 5 step auto-transformer speed controllers for speed selection. Uses 24V output from ITC controller. Dimensions: 86mm x 178mm x 100mm (Width x Height x Depth)
3 amp electronic controllers provide infinitely variable speed control from preset minimum to maximum. Features an On/Off switch with neon indicator and speed control knob. Built in 'Hard Start' auto maximum speed for a few seconds. Dimensions 150mm x 90mm x 65mm (Width x Height x Depth) Weight 0.5kg
6 amp electronic controllers provide infinitely variable speed control from preset minimum to maximum. Features an On/Off switch with neon indicator and speed control knob. Built in 'Hard Start' auto maximum speed for a few seconds. Dimensions 150mm x 90mm x 65mm (Width x Height x Depth) Weight 0.5kg
10 amp electronic controller provides infinitely variable speed control from preset minimum to maximum and feature On/Off Override switch for maximum speed. Neon indicator and built-in 'Hard Start' auto-maximum speed for a few seconds. Dimensions 167mm x 220mm x130mm (width x Height x Depth) Weight 1.3 Kg
For applications where regular switching is required at fixed periods or at different times on different days of the week, eg: offices, shops, pubs and restaurants.
The 7-day TimeSwitch gives twelve On or Off positions per day and can be set for 7 days. The cycle will repeat until changed.
- Analogue clock display and integral time switches for ease of setting.
- Manual override.
- Removable clear plastic cover protects TimeSwitch face.
- Volt free changeover contacts.
- Time base: 7 days.
- Shortest switching time: 2 hours.
- Maximum load: 16amp resistive (8amp inductive).
- Ambient operating temperature range -20°C to +85°C.
- Dimensions: 104 x 74 x 52mm (H x W x D).
- Supply voltage 220-240V/1/50Hz
Humidity Control is automatic and can be set to switch between 65 and 90%RH. An integral pullcord provides a manual override function if required. Can be wired for either ON/OFF or Trickle Boost operation. Set Point adjustable. Maximum switching load 1 amp inductive. Pullcord override indicator Ambient operating temperature 0°C to +40°C. Dimensions:87 x 87 x 33mm (H x W x D). Supply voltage 24V DC SELV. Humidity sensors should be sited approx. 100mm below ceiling level and not above cupboards, refer to siting details in fitting and wiring instructions supplied with product.
Operates Vent-Axia ventilating units on either a rise or a fall in humidity to control the damaging effects of condensation.
- Concealed adjustment.
- Setting range 20% to 80% RH.
- Ambient operating temperature 0°C to +50°C.
- Dimensions: 82 x 132 x 40mm (H x W x D).
- Rating 2A (1A inductive).
- Switching range 120-240V.
- Designed for use with controllers with ‘Auto’ mode facility.
- Single pole changeover contacts.
Automatically reacts to the deterioration of air quality, sensing tobacco smoke, smells and toilet odours to regulate mechanically ventilated areas, such as cinemas, pubs, clubs, restaurants, kitchens, toilets and conference rooms. The sensor switches when the air quality declines below an adjustable preset level. This is registered by a self-cleaning ceramic sensing head. The air quality sensor should not be used for the detection of combustible gases. Ambient operating temperature range 0°C to +50°C. MIN - MAX mode or direct Damper control. Dimensions:87 x 157 x 47mm (H xWxD) Surface mounted. 1 - 25 min O/R timer. Supply voltage 24V DC SELV.
A wall or ceiling mounted movement detector for use with any domestic Vent-Axia mains voltage product. Also suitable for use with Vent-Axia T-Series controllers on ‘Auto’ setting and ITC controllers on sensor mode. Visionex PIR can be wired for either On/Off or Trickle/ Boost operation.
- Fits any UK single gang mounting box.
- Adjustable timer overrun (5-25 minutes).
- Range of detection up to 10 metres.
- Designed to meet IP43.
- Ambient operating temperature range 0°C to +50°C.
- Maximum load: 2.5 amps/600W inductive. Not suitable for use with lighting.
- Internal use only.
- No switched live required for internal rooms and WCs.
- Double insulated.
- Volt-free contacts.
- Supply voltage 220-240V/1/50Hz.
20 amp electronic controller provides infinitely variable speed control from preset minimum to preset maximum via lid mounted potentiometer and features; On/Off Override contacts for remote switching Built-in 'Hard Start' auto-maximum speed for a few seconds. 24V (80mA) supply for remote sensors(lid potentiometer to be disconnected) 0-10v Input for remote sensor Motor Thermal protection connections (TP's) IP rating - IP54 Weight 2.3 Kg