HR30W
Combines filtration and ventilation
Filters indoor air and eliminates microscopic particles
Eliminates excess humidity during the winter months and gaseous pollutants by exhausting stale air and replacing it with fresh filtered air
Relieves the symptoms associated with respiratory problems
Select a product
The HR30W has been specifically designed to provide balanced ventilation with heat recovery for installation in bedrooms giving virtually silent overnight operation with a daytime boost option. Low velocity and low noise heat recovery ventilation with a pollen filter for improving the internal environment.
The HR30W is a through the wall model, with a range of control and length options. The unit is designed for continuous operation providing up to 70% heat recovery, effectively controlling internal relative humidity.The integral high efficiency pollen filter helps eradicate house dust mites to improve health and indoor air quality. Fresh pre-warmed air from the outside is continuously provided to the room with simultaneous extraction of stale, moist air.
An integral heat exchanger transfers heat from the outgoing stale air to the fresh air supply raising the temperature of the fresh air and most importantly reducing the relative humidity of the supply air.This provides control of condensation and odours and creates conditions which can eliminate house dust mites.
Two speed performance: Low 35m³/h and High 50m³/h. Specifically designed for installation in the bedroom.
Installation
Vent-Axia HR30W units require a 240mm x 160mm hole. Units should be fitted so that they slope towards the outside (nominal 1°) to assist in-built condensate drainage. The telescopic flange ( adjustable to fit walls 220mm to 280mm thick) covers cutting marks and provides a surface for forming a seal with the external wall surface.
Maintenance
Apart from removing odours, providing fresh air and recovering heat, this appliance extracts airborne impurities such as dust, dirt and grease. These gradually build up and detract from the efficiency and appearance of the appliance. Therefore to ensure peak performance, the appliance should be cleaned regularly. Filters should be replaced every six months or as conditions necessitate. The heat exchanger and grille should be washed in warm soapy water every twelve months or as conditions necessitate.
Power Consumption
Minimum
10.0W
Maximum
23.0W
Sound Levels
Extract Performance
m³/h
Intake Performance
m³/h
Watts
Sounds Levels
dB(A) @ 3m
Boost
Trickle
Boost
Trickle
Boost
Trickle
Boost
Trickle
50
35
40
30
23
10
28
N/A
DIMENSIONS:
A | B | C | D | E | F | G | Weight |
370 | 270 | 220-280 | 68 | 155 | 235 | 190 | 4.85kg |
For installation in walls from 280mm to 500mm thick. Supplied with white ABS plastic external grille.
Raadpleeg de tab Downloads voor technische informatie
ESTIMATED RUNNING COSTS
Calculate estimated running costs for this product using the tool below.
For average costs*, leave the default values in place or enter your own figures in the boxes to recalculate.
Where a product has multi speeds, a typical installation has been used for the below calculations. *Running cost does not include the use of the heater on the heater model
Based on the inputted figures, estimated running costs would be:
Overview
The HR30W has been specifically designed to provide balanced ventilation with heat recovery for installation in bedrooms giving virtually silent overnight operation with a daytime boost option. Low velocity and low noise heat recovery ventilation with a pollen filter for improving the internal environment.
The HR30W is a through the wall model, with a range of control and length options. The unit is designed for continuous operation providing up to 70% heat recovery, effectively controlling internal relative humidity.The integral high efficiency pollen filter helps eradicate house dust mites to improve health and indoor air quality. Fresh pre-warmed air from the outside is continuously provided to the room with simultaneous extraction of stale, moist air.
An integral heat exchanger transfers heat from the outgoing stale air to the fresh air supply raising the temperature of the fresh air and most importantly reducing the relative humidity of the supply air.This provides control of condensation and odours and creates conditions which can eliminate house dust mites.
Two speed performance: Low 35m³/h and High 50m³/h. Specifically designed for installation in the bedroom.
Installation
Vent-Axia HR30W units require a 240mm x 160mm hole. Units should be fitted so that they slope towards the outside (nominal 1°) to assist in-built condensate drainage. The telescopic flange ( adjustable to fit walls 220mm to 280mm thick) covers cutting marks and provides a surface for forming a seal with the external wall surface.
Maintenance
Apart from removing odours, providing fresh air and recovering heat, this appliance extracts airborne impurities such as dust, dirt and grease. These gradually build up and detract from the efficiency and appearance of the appliance. Therefore to ensure peak performance, the appliance should be cleaned regularly. Filters should be replaced every six months or as conditions necessitate. The heat exchanger and grille should be washed in warm soapy water every twelve months or as conditions necessitate.
Power Consumption
Minimum
10.0W
Maximum
23.0W
Sound Levels
Extract Performance
m³/h
Intake Performance
m³/h
Watts
Sounds Levels
dB(A) @ 3m
Boost
Trickle
Boost
Trickle
Boost
Trickle
Boost
Trickle
50
35
40
30
23
10
28
N/A
Technical
DIMENSIONS:
A | B | C | D | E | F | G | Weight |
370 | 270 | 220-280 | 68 | 155 | 235 | 190 | 4.85kg |
Models
For installation in walls from 280mm to 500mm thick. Supplied with white ABS plastic external grille.